User's Manual

Table Of Contents
RF Station Configuration
JUL 2001 Rev 03
57
Performing the RSSI Test
RSSI mode is used to measure the signal strength (fade margin) of a system. When running the test between
two units, the transmit unit is set to Transmit Test mode (using either the RF Station Configuration menu or
the Mode button). The receive unit is put into RSSI Test mode (using either the RF Station Configuration
menu or the Mode button). The Air LED on the receiving unit indicates the fade margin.
To run the RSSI test
1. Put the receiving unit into RSSI mode. See Setting the Operating Mode, page 49 or Setting Operating Mode
with the Mode Button, page 104. The Mode LED is orange when the unit is in RSSI mode.
2. Put the transmiting unit into Transmit Test mode. The Mode LED on the unit is red, indicating that
the unit is in transmit mode. See Setting the Operating Mode, page 49 or Setting Operating Mode with the
Mode Button, page 104.
3. Observe the color of the Air LED on the receiving unit. The Air LED is green when the signal strength is
acceptable.
4. To exit from the test, briefly disconnect power from the unit or press and hold the Mode button to
return to Normal mode.
Air LED Color Signal Strength
Green Reliable signal—greater than 15 dB fade margin
Orange Marginal signal—between 11 and 15 dB fade margin
Red Poor signal—less than 10 dB fade margin
Blank No signal at all