Setting System Symmetry Type (Base Station Only)
System symmetry type fixes the priority of the base unit when it polls remotes. The default "asymmetric"
setting alots the base one time slot for each time a remote is polled—this setting is useful when the base is
the access point to a large network. The "symmetric" setting alots the base one time slot per polling cycle. A
symmetric system gives the base station the same polling priority as a remote unit.
To set system symmetry type
1. From the Main Menu, select Radio Module Configuration and press
Enter. The Radio Module
Configuration menu is displayed.
2. Select System Symmetry Type and press
Enter. The data field highlights.
3. Scroll to the desired setting where:
4. Press Enter. The new setting is displayed in the "New" column.
5. Select Reboot New RF Configuration and press
Enter. The unit reboots and the AWE 120-24
Login menu is displayed. The unit now runs using the "Current" symmetry type for the amount of time
specified by the Current Test Minutes.
6. To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module
Configuration, Save Current Config to Flash. See Rebooting and Saving RF Module
Configurations, page 86.
7. Press
Esc to exit to the Main Menu.
asymmetric Base unit has higher priority than remotes: the base unit has one time slot
after every remote time slot. Default setting
symmetric Base unit has the same priority as all remotes: the base unit has one time
slot for every polling cycle
Radio Module Configuration
New Current Flash
Station Type Remote Unit Remote Unit Remote Unit
Station Rank (1-1000) 1 1 1
Center Frequency 2.4400 GHz 2.4400 GHz 2.4400 GHz
Security Password 1 (Hex) 1 1 1
Security Password 2 (Hex) 10 10 10
Security Password 3 (Hex) 100 100 100
Security Password 4 (Hex) 1000 1000 1000
Security Password 5 (Hex) 10000 10000 10000
Scrambling Code (Hex) 0 0 0
Acquisition Code (0-15) 0 0 0
Config Test Minutes (1-120) 30 30 30
Tx Power Level Adjust -> 0 dB 0 dB 0 dB
Base Station Only Parameters
Repeater Mode off off off
System Symmetry Type Asymmetric Asymmetric Asymmetric
Dynamic Polling Level (1-100) 1 1 1
Remote Station Only Parameters
Remote Unit RF Group (0-63) 0 0 0
Reboot New RF configuration Press Enter to Execute
Save Current Config to Flash Press Enter to Execute