User's Manual

Wi2Wi, Inc. Rev.1.1
Data Sheet, WLAN-Bluetooth Module– W2CBW009S
Dated: October 20, 2009
The content of this document is to be treated as strictly confidential and is not to be disclosed,
Reproduced or used, except as authorized in writing by Wi2Wi, Inc.
Copyright © 2009 Wi2Wi, Inc.
Page 19 of 20
10.2 Storage and Baking Instructions
W2CBW009S is an MSL3 grade part. After opening the bag, the parts should be:
a.
Stored as per J-STD-003 standard
b.
Mounted within 72 hours of factory conditions (<=30C, 60% RH)
If any of the above conditions is not met, the parts should be baked as listed below prior to assembly:
a.
S90C for 4 hours
b.
M125C for 12 hours
10.3 Recommended Reflow Profile
Figure 5: Reflow Profile
TBD
11 Disclaimers
Wi2Wi, Inc. PRODUCTS ARE NOT AUTHORISED FOR USE AS CRITICAL COMPONENTS IN
LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF
THE MANAGING DIRECTOR OF Wi2Wi, Inc.
The definitions used herein are:
a) Life support devices or systems are devices which (1) are intended for surgical implant into the body,
or (2) support or sustain life and whose failure to perform when properly used in accordance with the
instructions for use provided in the labeling can reasonably be expected to result in a significant injury
to the user. b) A critical component is any component of a life support device or system whose failure to
perform can be reasonably expected to cause the failure of the life support device or system, or to affect
its safety or effectiveness.
Wi2Wi does not assume responsibility for use of any of the circuitry described, no circuit patent licenses
are implied and Wi2Wi reserves the right at any time to change without notice said circuitry and
specifications.
11.1 Data Sheet Status
Wi2Wi, Inc. reserves the right to change the specification without prior notice in order to improve the
design and supply the best possible product. Updated information, firmware and release notes will
be made available on www.wi2wi.com. Please check with Wi2Wi Inc. for the most recent data