Installation Instructions

Outdoor Software Defined Radio (OSDR) platform
Installation & Cabling Manual - Edition 3.0
121
Grounding Cable, Continued
Grounding
cable (16 mm
2
)
termination
procedure
To terminate the 16 mm
2
grounding cable, proceed as follows:
Step Action
1
Cut the grounding cable (for 16 mm
2
) according to the distance
between equipment and grounding bar.
2
Use the blade to strip 1 cm from each end of the cable, as below:
3
Perform the following:
A: Slide the M5 grounding lug over the wires at one end of
the cable and crimp it with the special crimping tool (for 16
mm
2
).
B:
Cut the heat shrinkable tube in the middle in two equal
pieces in order to use one piece per cable side.
C:
Slide the one piece of the heat shrinkable tube over the
cable.
Heat it over rear grounding ring body and down on to
cable jacket using the hot air blower.
4
Repeat step 3 for the other end of the cable using the appropriate
terminal lug. Eventually both ends should be as follows:
M5 grounding lug (OSDR or outdoor AC PoNE side).
Appropriate grounding lug (grounding bar side).
End of procedure.
Continued on next page
~
~
1 cm
1 cm