6. Equipment Commissioning
52
WiBAS-OSDR TS, Continued
Procedure for WiBAS-OSDR TS with Panel Antenna, continued
Step Action
5
Log in to the aligned terminal station as described to Accessing a Radio Unit
on
page 29.
Go to Summary and check the RSSI & SNR value, as shown below:
Press the refresh button to get the latest value.
6
If the values are the expected ones, then secure the antenna to the final position.
Use the adjustable U-wrench to apply the final tightening torque to the bolts,
as follows:
M8 adjuster’s bolts max tightening torque 20 Nm.
M8 u-bolts nuts max tightening torque 15 Nm.
Do not over tighten.
Be very careful when tightening the adjustment bolts not to move the
antenna.
After alignment completion DO NOT leave radio unit RSSI receptacle without
cover. Covering receptacles protect against humidity penetration.
End of procedure.