User Manual

6. Equipment Commissioning
56
WiBAS-Connect TS
, Continued
Procedure for WiBAS-Connect TS with Parabolic Integrated Antenna
To perform WiBAS-Connect TS parabolic integrated antenna alignment, please follow the
steps below:
Step Action
1 Perform coarse alignment, as follows:
Use the respective spanner key to rotate the assembly on the pole so that the
antenna is “visually” aligned with the target base station sector.
Use compass and binoculars for alignment.
Use the RF planning values for aligning the assembly to the target base
station sector.
Use the adjustable U-Wrench to apply the final tightening torque according
the ANTENNA INSTALLATION LEAFLET values.
2 Power on the terminal station.
Connect the RSSI cable as described to RSSI cable connection procedure on page
42.
Continued on next page