77
WiBAS-Connect TS (Auto-Polarization Edition), Continued
Procedure for WiBAS-Connect Auto-Polarization TS with Parabolic Low Profile Antenna,
continued
Step
Action
5
Perform the following actions:
Remove the RSSI cable from TS and after 2-3 seconds inserted again (as
described to
RSSI cable connection procedure on page 42).
Wait 30 seconds. During boot process the voltmeter shows ~2.5 V.
Please do not perform any action till the boot process of the TS is completed.
After boot process the TS starts automatic process scan (horizontal), and:
S/W selects F1 frequency (in horizontal polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
S/W selects F2 frequency (in horizontal polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
For QI values please refer to QI table on page 93.
Continued on next page