89
Appendix B – Inband Management Connection
Troubleshooting
Scope
Appendix B provides the following fail-safe procedures:
Fail-safe
procedure
When used Physical
mngt
connection
Fail-safe IP
Address
Fail-safe procedure 1
(arp-s commands)
Communication with
WiBAS cannot be
established.
Inband
10.255.255.254
Fail-safe procedure 2
(netsh commands for
Windows 10 users)
Communication with
WiBAS cannot be
established and,
the execution of fail-safe
procedure 1 (arp-s
commands) also fails.
Concerns only
Windows 10 users.
Fail-safe procedure 3
(outband)
None of the above fail-
safe procedures solve
the communication
problem.
Outband
192.168.255.254
Prerequisites
Prior to performing a fail-safe procedure, ensure that:
The laptop user has admin rights.
The laptop firewall hasn't blocked Ping and ICMP Echo Replies.
Fail-safe
procedure 1
(arp-s
commands)
To apply fail-safe inband IP address, please follow the steps below:
Prior to starting fail-safe procedure 1, ensure that an inband
physical management connection has been implemented on
node.
Step Action
1 Setup to laptop the Ethernet IP address 10.255.255.253 with
subnet mask 255.255.255.252.
2 Open Windows Command Prompt.
Continued on next page