Double clicking on a parameter opens up a window that will allow you to set a new value. For
this example, scroll to the bottom of the list and double click the parameter named “VTIM”. From
the parameter description above, we can see that VTIM corresponds to the parameter
MaxCVChargeTime, which sets the maximum time that an OC will charge a battery in CV mode.
In the value box, change the number to 3600, meaning 3600 seconds (or 1 hour), and click
“Send”.
The parameter will now be changed on your system. Close the window and you will see that the
parameter value has been updated. To save the parameter to memory so that it will remain
3600 across reboots, click the “Store All” button. NOTE: This will save all parameters that have
been changed. If you only wish to save certain parameters, set and save those first before