RST 20i3 58
RST 20i3 Standard version for power applications – multi-phase systems, 250 V switching applications and low voltage Application example General The 3 pole connectors are available in four versions: the standard version for general power applications, a version for low voltage up to 50 V with ground conductor; another version for switching applications up to 250 V, and finally a green coding for applications in multi-phase systems. Both connectors are mechanically coded.
RST 20i3 Connector for cables of Ø 6 – 10 mm and 10 – 14 mm Female connector Unmounted with cable gland. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Coding Power 250 V L, N, U Power 250/400 V 50 V +U Switch.func. 250 V 1, 2, U 1, 2, U 1, 2, 3 Cable diameter in mm 6 – 10 10 – 14 6 – 10 10 –14 6 – 10 10 –14 6 – 10 10 –14 Color Part No. gray black gray black green brown light blue Part No.
RST 20i3 Connector, angled for cables of Ø 6 – 10 mm and 10 – 14 mm Female connector Unmounted with cable gland. 90° angle. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Coding Power 250 V L, N, U Power 250/400 V 50 V +U Switch.func. 250 V 1, 2, U 1, 2, U 1, 2, 3 Cable diameter in mm 6 – 10 10 – 14 6 – 10 10 –14 6 – 10 10 –14 6 – 10 10 –14 Color Part No. gray black gray black green brown light blue Part No.
RST 20i3 Connector for cables of Ø 13 – 18 mm Female connector Unmounted with cable gland. See Technical Data for sheath and insulation strip lengths. Application Coding Cable diameter in mm Color Part No. with screw connection1) Wire mm2 rigid 0.75 – 6.0 2) fine-stranded without ferrules stranded Power 250 V Power 250/400 V L, N, U 1, 2, U 13 –18 gray black 96.031.4553.0 96.031.4553.1 13 –18 green 96.031.4555.7 Male connector Unmounted with cable gland and with locking device.
RST 20i3 Splitter connector Female connector Unmounted with cable gland. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Coding Power 250 V L, N, U Power 250/400 V 1, 2, U Cable diameter in mm 6 – 10 10 – 14 6 – 10 10 – 14 Color Part No. gray black gray black green Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.5 with ferrules stranded 0.75 – 1.
RST 20i3 M 25 device connector, standard Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from outside. See the Technical Data for insulation strip lengths as well as the ferrules to be used. For spacer rings for unlocking at the device connectors, see Accessories. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.
RST 20i3 M 20 device connector, modular, straight Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from inside. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.5 with ferrules stranded 0.75 – 1.
RST 20i3 M 16 device connector, modular, straight Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from inside. . See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.5 with ferrules stranded 0.75 – 1.
RST 20i3 M 16 device connector, modular, 7° angle Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from inside. Angled 7°, thread M16. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.
RST 20i3 M 20 device connector, modular, angled Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from inside. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.5 with ferrules stranded 0.75 – 1.
RST 20i3 M 25 device connector, modular, angled Female connector Correct positioning guaranteed due to flattened thread. Fastening with screws from inside. See the Technical Data for insulation strip lengths as well as the ferrules to be used. Application Power 250 V Power 250/400V 50 V +U Switch. funct. 250 V Coding L, N, U 1, 2, U 1, 2, U 1, 2, 3 Color Part No. Part No. with spring clamp connection Ferrules Wire mm2 rigid 0.5 – 2.5 fine-stranded 0.5 – 1.5 with ferrules stranded 0.75 – 1.
RST 20i3 Cable assemblies 1.5 mm2, 16 A H05VV-F 3G1.5 containing halogen Power 250V: U = GN/YE N = BU L = BN Power 250/400V: U = GN/YE 1 = BU 2 = BN Cable1) and shrinkage tube Female – Male Extension cable Locking device yes Female – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul. strip length 9 mm Color: black Application Length2) m Part No. Power 250 V L, N, U 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Grounding connector 1.5 2.5 Power 250 V/400 V 1, 2, U 1.0 2.0 3.
RST 20i3 Cable assemblies 1.5 mm2, 16 A H07RN-F 3G1.5 Insulating rubber compound Power 250V: U = GN/YE N = BU L = BN Power 250/400V: U = GN/YE 1 = BU 2 = BN Cable1) and shrinkage tube Female – Male Extension cable Locking device yes Female – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul. strip length 9 mm Color: black Application Length2) m Part No. Power 250 V L, N, U 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Grounding connector 1.5 2.5 4.0 8.
RST 20i3 Cable assemblies 2.5 mm2, 20 A H05VV-F 3G2.5 containing halogen Power 250V: U = GN/YE N = BU L = BN Power 250/400V: U = GN/YE 1 = BU 2 = BN Cable1) and shrinkage tube Female – Male Extension cable Locking device yes Female – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul. strip length 9 mm Color: black Application Length2) m Part No. Part No. Male – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul.
RST 20i3 Cable assemblies 2.5 mm2, 20 A H07RN-F 3G2.5 Insulating rubber compound Power 250V: U = GN/YE N = BU L = BN Power 250/400V: U = GN/YE 1 = BU 2 = BN Cable1) and shrinkage tube Female – Male Extension cable Locking device yes Female – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul. strip length 9 mm Color: black Application Length2) m Part No. Part No. Male – Free end Connection cable Wire ends ultrason. welded Sheath strip length 35 mm Insul.
RST 20i3 Distribution units Distribution unit 1I/3O Application Coding Color Part No. with mounting Locking device Input Outputs Power 250 V Power 250/400 V 50 V +U Part No. option yes 1 3 without mounting option Locking device yes Input 1 Outputs 3 Male ,3 pole Female, 3 pole L, N, U gray black 96.030.0153.0 96.030.0153.1 96.030.0253.0 96.030.0253.1 1, 2, U green 96.030.0155.7 96.030.0255.7 1, 2, U brown 96.030.0151.4 96.030.0251.
RST 20i3 Accessories – Cover pieces Female connector 2 to 3 pole Color Part No. gray black Part No. not captive against loss Pole 2 – 3 pole Safe locking unused male connectors device captive against loss Pole 2 – 3 pole Safe locking unused male connectors device 05.564.4453.0 05.564.4453.1 99.415.6205.2 99.416.6205.2 Male connector 2 to 3 pole Color Part No. gray black Part No.