User's Manual

Wifx L1 User manual revision 1.0
EN
6
3 REGULATIONS
3.1 VERSION 863-870MHZ BAND
3.1.1 EUROPE / CE
The Wifx L1 8XX (863-870MHz) version complies with requirements RED standard requirements:
RF
ETSI EN 300 220-1 V3.1.1 (2017-02)
ETSI EN 300 220-2 V3.2.1 (2018-06)
EMC
ETSI EN 301 489-1 V2.2.3 (2019-11)
ETSI EN 301 489-3 V2.1.1 (2019-03)
EN 55032:2015/A11:2020
EN 55035:2017/A11:2020
EN IEC 61000-3-2:2019
EN 61000-3-3: 2013/A1: 2019
Human safety
EN 50665:2017
Electrical safety
EN 62368-1:2014/A11:2017
TABLE 3: CERTIFICATION COMPLIANCE VERSION 863-870MHZ FOR EUROPE
For use in Europe, the Wifx L1 must comply with the ERC 70-3 requirements regarding duty cycle and maximum
EIRP. These parameters are summarized in the following table:
ERC 70-3 Band
Frequency (MHz)
Power
Duty cycle
h1.3
863 865
14dBm ERP
0.1%
h1.4
865 868
14dBm ERP
1%
h1.5
868 868.6
14dBm ERP
1%
h1.6
868.7 869.2
14dBm ERP
0.1%
h1.7
869.4 869.65
27dBm ERP
10%
h1.8
869.7 870
7dBm ERP
No requirement
h1.9
869.7 870
14dBm ERP
1%
TABLE 4: DUTY CYCLES AND MAXIMUM EIRP VERSION 863-870MHZ FOR EUROPE
If the antenna is changed, the output power must be adjusted to take the antenna’s gain into account and avoid
exceeding the values defined by the ERC 70-3 regulation.
Warning: some countries in Europe may have a specific frequency range, a maximum EIRP and duty cycle regulation.
Please check the local regulations before installing and using the Wifx L1 863-870MHz version.
For countries outside Europe, please check that the frequency range, the maximum allowed EIRP and duty cycle are
authorized.