Owner's manual
without PN specification, PN 16, PN 40 or 150 lbs,
300 lbs, 600 lbs
Flange PVDF PN 16
Product temperature standard version, depending on the meas. cell seal
9)
- FKM (VP2/A) -20 … +120 °C (-4 … +248 °F)
- EPDM (A+P 75.5/KW75F) -40 … +120 °C (-40 … +248 °F), 1 h: 140 °C/284 °F
cleaning temperature
- FFKM (Kalrez 6375) -10 … +120 °C (+14 … +248 °F)
- FFKM (Chemraz 535) -30 … +120 °C (-22 … +248 °F)
Product temperature version with extended temperature range, depending on the meas. cell seal
as well as order specification
- FKM (VP2/A) -20 … +150 °C (-4 … +302 °F)
- EPDM (A+P 75.5/KW75F) -40 … +150 °C (-40 … +302 °F)
- FFKM (Kalrez 6375) -10 … +150 °C (+14 … +302 °F)
- FFKM (Chemraz 535) -30 … +150 °C (-22 … +302 °F)
Vibration resistance mechanical vibrations with 4 g and 5 … 100 Hz
10)
Shock resistance Acceleration 100 g
11)
Electromechanical data - version IP 66/IP 67
Cable entry/plug
12)
- Single chamber housing l 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l 1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
- Double chamber housing l 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; plug M12 x 1 for
the external indicating and adjustment unit
(optional)
or:
9)
With process fitting PVDF, max. 100 °C (212 °F).
10)
Tested according to the regulations of German Lloyd, GL directive 2.
11)
Tested according to EN 60068-2-27.
12)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
42 Process pressure transmitter IPT-11 Vers. 4.0 - ceramic sensor • 4 … 20 mA
10 Supplement
37301-EN-100302