Owner's manual

l 1 x closing cap ½ NPT, 1 x blind stopper
½ NPT, plug M12 x 1 for the external indicating
and adjustment unit (optional)
or:
l 1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for the
external indicating and adjustment unit (optio-
nal)
Spring-loaded terminals for wire cross-sec-
tion up to
2.5 mm² (AWG 14)
Indicating and adjustment module
Voltage supply and data transmission through the sensor
Indication LC display in dot matrix
Adjustment elements 4 keys
Protection rating
- unassembled IP 20
- mounted into the sensor without cover IP 40
Materials
- Housing ABS
- Inspection window Polyester foil
Voltage supply
Operating voltage
- Non-Ex instrument 12 36 V DC
- EEx-ia instrument 12 30 V DC
- Exd instrument 18 36 V DC
Operating voltage with lighted indicating and adjustment module
- Non-Ex instrument 20 36 V DC
- EEx-ia instrument 20 30 V DC
- EEx-d-ia instrument 20 36 V DC
Permissible residual ripple
- < 100 Hz U
ss
< 1 V
- 100 Hz 10 kHz U
ss
< 10 mV
Load see diagram
Process pressure transmitter IPT-11 Vers. 4.0 - ceramic sensor 4 20 mA 43
10 Supplement
37301-EN-100302