AVOIDING HUM IN THE AUDIO (AS A RESULT OF A GROUND LOOP)
Ahum created by a ground loop can often be eliminated by connecting a capacitor in series with the audio
line shield to the transmitters ground. This method also maintains good RF shielding. Determining the
effectiveness of this method for your installation usually requires some experimentation. See Figure 7.
CONNECTING THE T35 TO A RECORDING DEVICE
Use the Audio Line Out jack for monitoring, recording, or routing processed audio to another sound system.
9
.01 uF Ceramic
Disc Capacitor
I
n Phase
3–Pin Connector
.01 uF Ceramic
D
isc Capacitor
12
3
B
reaking A Ground Loop when 
Connecting to a Unbalanced Line
B
reaking A Ground Loop when 
Connecting to a Balanced Line
FIG. 7: CONNECTING TO A BALANCE/UNBALANCED LINE
FIG. 8: AUDIO LINE OUTPUT