Instruction manual

FOR YOUR SAFETY, READ BEFORE LIGHTING
WILLIAMS GAS CONTROL VALVE P322051 (OR) P322052 (OR) P500419 (OR) P5004_,0
r WARNING: If you do not follow these instructions exactly, a fire or explosion I
may result causing property damage, personal injury or loss of life,
I
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell around the appliance ares
for gas. Be sure to smell next to the floor because some
gas Is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
DO not touch any electric switch; do not use any
phone In your building.
Immediately cell your gas supplier from s neighbor's
phone. Follow the gas suppller's instructions.
C,
D.
If you cannot reach your gas supplier, call the fire
department.
Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
tom by hand, don't try to repair it, call qualified serv-
ice technician. Force or attempted repair may result In a
flro or explosion.
Do not use this appliance If any part has been under
water, immediately call s qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
OPERATING INSTRUCTIONS
1. STOP! Read the sefety information above.
2. TOm off all electric power to the appliance (if applicable).
3. Open control access panel.
4. Tom temperature dial clockwise F_ to "LO'"
5. Push in gas control knob slightly and turn
olookwlee !-_ to "OFF."
TEMPERATURE
DIAL GAS CONTROL
"'_@._:/_--"_@1 _ @1/ KNOB SHOWN
"_'F/_ \l F_',_%'_/_ IN OFF
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob Is pushed in slightly. Do not force. 11.
6. Welt five (5) minutes to clear out any gas, then smell for
gas, including near the floor, if you then smell gas, stopl 12.
Follow "B" in the safety Information above. If you don't
smell gas, go to next step.
7. Loosen wlngnut end open the pilot observation door (if 13.
equipped). 14.
8. Find pilot--follow metal tube from gas control. The pilot is
mounted on side of burner.
9. Push In gas control II _
knob slightly and turn
counterclockwise
to "PILOT."
10. Push in control knob all the
way end hold In. Immediately THERMO- PILOT
light the pilot. COUPLE BURNER
Continue to hold the control knob In for about one (1)
minute after the pilot is lit. Release knob end It will
pop back up. Pilot should remain lit. If It goes out,
repeat sfop$ 5 through 10.
If knob does not pop up when released, stop and
Immediately ceil your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
Close pilot observation door, tighten wingnut
(if equipped).
Torn gas control knob counterclockwise _'_ to "ON':
Sensing bulb is now activated. Set temperature dial to
desired temperature (1 - 5).
Close control access panel.
Torn on all electric power to the appliance
(if applicable).
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power to the appliance If serv-
Ice is to be performed (if applicable).
2. Open control access panel.
3. Push In gas control knob slightly and tum
clockwise F-_ to "OFR" Do not force.
4. Close control access panel.
WARNING: DUE TO HIGH SURFACE TEMPERATURES -- KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY FROM FURNACE.
IMPORTANT: KEEP BURNER AND CONTROL COMPARTMENT CLEAN.
CONNECTION WIRING DIAGRAM FOR BUILT-IN THERMOSTAT MODELS
SHUT OFF 0E-_IC_
-
BLACK
BLACK
GAS VALVE
RE]_OTE BULB
LZGE_O
-- FACTORY WIRED LOW VOLTAGE
NOTES: F k_Y 0F 1_ 01_lU_. NR[ _
€[ m'LAC_ US[O_y t_. 4,_,
IK_JI,,A'nG_1G6".C.AW
vm[ oR I_/JIVAL_T.FORRDD.
_ Cml_llo_ us[ NO,18A_O
m _lZO mt ATZZ_TI_ (:ml-)
--10--