Use and Care Manual

Caring for Your Heater
Care – 19
How To Care For Your Heater
WARNING: Danger of bodily injury or death. Turn
off electric power supply at the disconnect switch,
fuse box or service panel before removing any
doors or access or service panels from the unit.
ANNUAL UPKEEP NEEDED
It is recommended that a qualified service technician perform
these checks at the beginning of each heating season.
CABINET FINISH
Clean the cabinet with a damp rag. Never use abrasive cleaners.
Cabinets are finished in heat resistant powder coated finish - DO
NOT refinish with wall paint.
REMOVABLE CABINET TOP (350, 500, & 650 MODEL SERIES)
For ease of cleaning, access or replacement of internal parts, the
top of this heater can be removed by following these steps:
1. Remove the three (3) brackets on the rear of the heater
securing the cabinet top to the back plate.
2. Pull the cabinet top forward and lift up. Reinstall the cabinet
top by reversing the procedures noted above. (Figure 19).
Note: Take special care to engage the six (6) clips located on the
bottom of the cabinet top into the top flange of the heater sides.
HEATER AREA
Keep the area near the heater clear and free from combustible
materials, gasoline and other flammable liquids and vapors.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not be blocked.
Do not put anything in or on the heater cabinet.
For better circulation and more effective heating, do not place
obstructions, furniture or other items closer than four feet to the
front of the cabinet or two feet from each side of the cabinet.
CLEANING BLOWER (IF EQUIPPED)
Shut off electricity. Clean any lint or dirt from fan blades, fan motor
and exposed air passages. Annually put two drops of SAE 20 oil
in each of the two cups or oil tubes.
PILOT BURNER
Light the pilot using the instructions in OPERATING YOUR
HEATER. Leave the thermostat at the lowest setting.
The pilot flame should surround 1/2 to 5/8 inches of the generator
tip. If the flame needs adjusting, do it as follows:
ADJUST PILOT BURNER
1. Insert a small screwdriver, adjust the flame as needed. Turn
the screw counterclockwise to increase the flame, clockwise to
decrease.
2. Turn the thermostat to the highest setting. The main burners
should light quickly and smoothly. Turn the thermostat to its
lowest setting. Main burners should go out. The pilot should
remain lit.
3. Refer to Figure 20.
VENTING SYSTEM
Make sure that no parts of the vent air system are blocked, rusted
or damaged. Clean or replace before using the heater.
BURNER CLEANING
Check the burner. If cleaning is required, contact a qualified
service technician to clean and service burner.
FIGURE 19 Removable Cabinet Top
FIGURE 20 Pilot Adjustment Screw