Use and Care Manual

Caring for Your Furnace
24
How To Care For Your Furnace
WARNING: Danger of bodily injury or death. Turn
off electric power supply at the disconnect switch,
fuse box or service panel before removing any
doors or access or service panels from the unit.
CABINET FINISH
Clean the cabinet with damp rag. Never use abrasive cleaners.
Cabinets are finished in heat resistant powder coated finish - DO
NOT refinish with wall paint.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not be blocked.
Do not put anything in or on the furnace cabinet.
For better circulation and more effective heating, do not place
obstructive furniture closer than four feet to the front of the cabinet
or two feet to either side of the cabinet.
FURNACE AREA
Keep the area near the furnace clear and free from combustible
materials, gasoline, and other flammable liquids and vapors.
ANNUAL UPKEEP NEEDED
It is recommended that a qualified service technician perform
these checks at the beginning of each heating season.
CLEANING AND OILING
Shut off electricity, and then remove cabinet door and front panel.
Clean any lint or dirt from fan blades, fan motor, and exposed air
passages. Use a brush.
Put 5 drops of SAE 20 oil in each of the two cups or oil tubes on
the fan motor, See Fig. 36, below.
PILOT BURNER
Light pilot using instructions in OPERATING YOUR FURNACE
(on pages 22 and 23, depending on your model). Leave
thermostat at lowest setting.
Pilot flame should surround 3/8 to 1/2 inch of the thermocouple
tip. Refer to Fig. 28, Page 25. If flame needs adjusting, do it as
follows:
ADJUST PILOT BURNER (Page 25 Fig 28)
1. Remove screw cover over pilot adjusting screw.
2. Insert small screwdriver, adjust flame as needed. Turn screw
counterclockwise to increase flame, clockwise to decrease.
3. Turn thermostat to highest setting. Main burners should light
quickly and smoothly. Turn thermostat to lowest setting. Main
burners should go out. Pilot should remain lit except for
electronic ignition models. See Page 23.
BURNER FLAME
Start the furnace and let it operate about 10 minutes then look at
the burner flame. Flames should be soft and blue, see Fig. 28. If
flames appear abnormal, contact the gas company or a qualified
service technician immediately.
VENTING SYSTEM
Make sure that no parts of the vent air system are blocked or
rusted. Clean or replace before using furnace.
FIGURE
27

Summary of content (3 pages)