Instructions / Assembly
REV.9/27/05 Page 2 of 7
WIRED WALL MOUNT THERMOSTAT OPERATION
FUNCTIONS
1. ROOM TEMP – Current room temperature.
2. F – Degrees Fahrenheit (C Indicates degrees Celsius)
3. FLAME ICON – Indicates APPLIANCE IS ON.
4. SET- Indicates TS/R-3 is in thermostat mode.
5. DASHES – Indicate thermostat mode is being disabled. When
TS-3 is not in the thermostat mode. The word (SET) will not appear.
1. This TS/R-3 Wired wall Thermostat has ON, OFF, and SET functions that are activated by
pressing the buttons on the face of the TS-3.
2. If the LCD will not come on, check the 3V-button cell battery.
SETTING MANUAL OPERATION
1. When the ON button on the TS-3 is pressed a flame icon on the LCD screen will appear when
the appliance is ON.
2. When the appliance is OFF the flame icon will not appear.
SETTING THERMOSTAT OPERATION
1. If the TS-3 is in the thermostat mode the word (SET) will appear on the LCD screen.
2. When the SET button is pressed the temperature digits will begin to flash.
3. While the temperature digits are flashing use the ON button to increase the set
temperature or use the OFF button to decrease the set temperature to your desired
temperature.
4. When the desired temperature setting is reached press the SET button, again and the
word SET will appear on the LCD screen and now the thermostat will automatically send
an ON or OFF signal to the appliance.
5. To disengage the thermostat mode push the OFF button or push and hold the SET button
until (2) dashes appear on the LCD screen. When you release the SET button this will
disengage the thermostat mode and the word SET will disappear from the LCD screen.
SETTING
0
F /
0
C SCALE
The factory setting for temperature is degrees Fahrenheit (
0
F ) . To change this setting to Centigrade (
0
C ), you must press and hold
both the ON and OFF buttons on the transmitter at the same time until the LCD displays the change. If you want to convert back,
repeat the above procedure.
THERMO UPDATING FEATURE
This SKYTECH wired wall thermostat has a THERMO UPDATING Feature built into its software. The THERMO UPDATING Feature
operates in the following manner, but only in the THERMOSTAT MODE
:
The TS-3 normally reads the ROOM temperature every 2 minutes checking the ROOM temperature against the SET temperature and
then sends a signal to the appliance.
NOTE: When locating the TS-3 on a wall remember it should be kept away from direct sources of heat such as heating appliance,
incandescent lighting, and direct sunlight. Leaving the TS-3 in direct sunlight, for example, will cause its heat-sensing diode to read the
room temperature higher than it actually is; if in THERMOSTAT mode, it may not turn on the appliance even if the ambient ROOM
temperature is below the SET temperature.
ROOM
TEMP
1
2
3
SET
ROOM
TEMP
SET
5
4
ROOM
TEMP
ROOM
TEMP
SET
ROOM
TEMP
SET
ON
SET
OFF