Instructions / Assembly
REV.9/27/05 Page 3 of 7
INSTALLATION INSTRUCTIONS
WALL MOUNTING THE TS-3 THERMOSTAT
1. Remove face from backing plate as shown in Figure #1 then locate the
TS-3 to where the (2) thermostat wires from the appliance can be
pulled through the hole on the backing plate and connect them to the (2)
terminal screws.
2. After locating the (2) two mounting holes and mark the holes on the wall.
3. Use the (2) two dry wall anchors and screws (that are supplied) to mount
the base plate to the wall as shown.
4. Thermostat can also be mounted onto an existing (Plastic) electrical box.
5. Base plate should be mounted level on the wall for best operation
6. Reinstall the face to the backing plate this is done by sliding the face in and
down about 1/2” then check that the (2) male terminal connectors on the face
are engaged in the female terminal connectors on the backing plate. As shown
in Figure #1
GENERAL INFORMATION
WARNING
This TS-3 wired wall thermostat must be installed exactly as outlined in these instructions. Read all instructions completely before
attempting installation. Follow instructions carefully during installation. Any modifications of the TS-3 or any of its components will void
the warranty and may be pose a fire hazard.
Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult gas appliance manufacturer’s instructions
and wiring schematics for proper placement of all wires. All electronic modules are to be wired to manufacturer’s specifications.
WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote
should install the remote control system. Incorrect wiring connections WILL cause damage to the gas valve or electronic module
operating the gas appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES - ELECTRONIC SPARK IGNITIONS – OTHER APPLIANCES
This TS-3 wired wall thermostat connects to a millivolt gas valve, electronic spark ignition systems or other heating appliances as
shown below in Figure #3, Figure #4, & Figure #5. Connect 18 gauge stranded or solid wires from the TS-3 wired wall thermostat to
the gas valve, or electronic module.
Figure #3(Millivolt Valve) Figure #4 (Electronic Spark System)
ROOM
TEMP
ON
OFF
SET
WALL
TERMINAL BLOCK
ON MILLIVOLT
GAS VALVES
TH
TP
TP
TH
Thermopile &
Pilot Assembly
TS-3 Wired
Wall Thermostat
ROOM
TEMP
ON
OFF
SET
(2) Screw terminals
to connect wires
from millivolt valve
ELECTRONIC MODULE
TR
TH
neutral wire
24VAC
hot wire
120VAC Input
110/24VAC
Transformer
TS-3 Wired
Wall Thermostat
ROOM
TEMP
ON
OFF
SET
(2) Screw terminals
to connect wires
from electronic module