Install Instructions

6 Description and function
6.1 Product description (see Fig. 1a)
1 Terminal box 6 Motor housing
2 Suction side 7 Cable entry
3 Pump housing 8 Capacitor (only for single phase pumps)
4 Discharge side 9 Venting plug (only on some types)
5 Condensate outlet 10 Rating plate
6.2 Design of pump and motor
This wet rotor pump is designed to have all rotating parts surrounded by the liquid being pumped and
is suitable for single or three phase operation (see pump rating plate). A shaft seal, which would be sub-
ject to wear and maintenance is not required. Depending on the design of the pump, the system fluid
lubricates the sleeve bearings and cools both bearings and motor. The pump is maintenance-free and
requires no further maintenance after the air bleeding procedure during the initial start-up (no after
start-up maintenance).
The Wilo model TOP-Z is specially designed for use in conjunction with drinking water circulation sy-
stems. Thanks to its design and materials used in its construction the pump is resistant to corrosion
from elements in domestic hot water ( drinking water). All materials coming in contact with the deli-
very medium are NSF/ANSI 61 certified.
6.3 Functions
Speed setting of TOP-S.../TOP-Z... pumps (Fig. 5 and Fig.6)
The required speed of the pump can be adjusted manually in 2 positions (Max. and Min.) by mo-
ving the switch connector to the relevant socket. Procedure see Chapter “8.2 speed setting”.
Ensure power is turned off prior to changing speeds!
7 Installation and electrical connection
Installation and electrical work in compliance with any local codes and by quali-
fied personnel only!
7.1 Installation
x
The pump must be installed in a dry, well ventilated and frost-free place.
x
The pump must be installed in an easily accessible position to facilitate inspection or replacement.
x
The pump should never be located at the lowest point of the piping system, where dirt and se-
diment collect. Nor should it be located at the highest point of the piping system, where air ac-
cumulates. Please ensure at least a minimum of three pipe diameters of straight on the suc-
tion side of the pump.
ENGLISH
6
WARNING!
Bodily injury
Existing regulations for the prevention of accidents must be observed.
WARNING!
Electrical shock hazard
Dangers caused by electrical energy must be excluded.
National Electrical Codes, local codes and regulations must be followed.
CAUTION!
Possible damage of the pump
Foreign materials such as dirt and solder can effect the pump operation.
x
It is recommended that any welding and soldering work be done before installing
the pump.
x
Thoroughly flush the system prior to installing and operating the pump.
x
Foreign material in the system resulting from construction may damage the pump
and is not warrantable.
01-12.qxd:2058935_NAMEX_USA_1b12.qxd 06.03.2008 9:20 Uhr Seite 6