Install Instructions

115V 1ph
P1 P2 C2 C1 N L
115V/1/60 from power
Alimentation
e
n courant 115V/1/60
115V/1/60 del
suministro electrico
supply
Thermal Overload Circuit
250Vac/1 Amp NC contact.
Contact normalement fermé
pour circuit de protection
thermique 250Vac/1 Amp
Circuitos termicos de sobre
carga 250Vac/1 Amp
contacto NC.
DO NOT CONNECT DIRECTLY
NO CONECTE DIRECTAMENTE
AL SUMINISTRO ELECTRICO
NE PAS ALIMENTER EN
COURANT ELECTRIQUE
TO POWER SUPPLY
G
ROUND
T
ERRE/TIERRA
L
N
115V/1/60 coil, 1 Amp
115V/1/60 resistencia,
1 Amp max caida
(por otros)
max draw (by others)
Bobine relais 115V/1/60,
intensité max 1 Amp
(non fournie)
Fig. 8a