Instructions / Assembly

Copyright 2018, Wilsonart LLC 5
Boiling Water
Resistance
Slight Effect (Gloss)
No Effect (Other Finishes)
Slight Effect (Gloss)
No Effect (Other Finishes)
High Temperature
Resistance
Slight Effect (Gloss)
No Effect (Other Finishes)
Slight Effect (Gloss)
No Effect (Other Finishes)
Impact Resistance
40” (1016mm)
23.5” (600mm)
Radiant Heat
Resistance
200 seconds
> 200 sec.
Dimensional Stability
Machine Direction
Cross Direction
0.5%
0.8%
1.1% (max.)
1.4% (max.)
Surface Wear
Resistance
(cycles)
Meets or Exceeds 400
350 (min.)
Formability 5/16” radius (7.93mm)
7/16” radius (11mm)
9/16” radius(14.7mm)
Blistering 45 seconds
> 40 seconds
*Radius for face is actually the radius of the form around which the laminate is postformed. The
radius for back is actually the radius to which the decorative face is postformed.
Physical Properties of Postforming Laminate
ISO 4586 Test
Typical Wilsonart
Type 350
ISO 4586-3
HGP
Thickness
0.039” ± 0.005”
(0.99mm
±
0.13mm)
0.039” ± 0.005”
(1mm
±
0.12mm)
Appearance
N/A N/A
Light Resistance
Slight effect Slight effect
Cleanability (cycles)
10 20
Stain Resistance
Reagents 1-10
Reagents 11-15
No effect
Slight effect
No effect
Moderate effect
Boiling Water
Resistance
Slight Effect (Gloss)
No Effect (Other Finishes)
Slight Effect (Gloss)
No Effect (Other Finishes)
High Temperature
Resistance
Slight Effect (Gloss)
No Effect (Other Finishes)
Slight Effect (Gloss)
No Effect (Other Finishes)
Impact Resistance
55” (1397mm) 31.5” (800mm)
Radiant Heat
Resistance
205 seconds > 200 sec.
Dimensional Stability
Machine Direction
Cross Direction
0.5%
0.8%
1.1% (max.)
1.4% (max.)
Surface Wear
Resistance
(cycles)
Meets or Exceeds 400 350 (min.)
Formability*
*5/16” face (7.93mm)
*3/8” back (9.52mm)
*9/16” face (14.27mm)
*3/4” back (19.05mm)
Blistering
65 seconds
> 40 seconds
*Radius for face is actually the radius of the form around which the laminate is postformed. The
radius for back is actually the radius to which the decorative face is postformed.
Typical Fire Test Data
High-pressure laminates are subject to Flame Spread and Smoke Developed standards in structures
where codes establish such conditions.