Specification
Table Of Contents
- PART 1 - GENERAL
- 1.01 SECTION INCLUDES
- A. Standard Decorative Laminates.
- B. High Definition Laminates.
- C. Solicor Laminates.
- D. x You Laminates.
- E. Virtual Design Library Laminates.
- F. Markerboard Laminates.
- G. Chalkboard Laminates.
- H. Fire-Rated Decorative Laminates.
- I. Compact Laminates.
- J. Chemical-Resistant Decorative Laminates.
- K. High Wear Decorative Laminates.
- L. Cabinet Liners.
- M. Phenolic Backer Sheets.
- N. Decorative Edges and Edgeband.
- O. Accessory Materials.
- 1.02 RELATED REQUIREMENTS
- A. Section 01 3000 - Submittals.
- B. Section 06 4116 - Plastic-Laminate-Clad Architectural Cabinets.
- C. Section 06 4219 - Plastic-Laminate-Clad Wood Paneling.
- D. Section 08 1423.16 - Plastic-Laminate-Faced Wood Doors.
- E. Section 10 2113.16 - Plastic-Laminate-Clad Toilet Compartments.
- F. Section 12 3530.13 - Kitchen Casework.
- G. Section 12 3623.13 - Plastic-Laminate-Clad Countertops.
- 1.03 REFERENCES
- A. Reference Standards:
- 1. ASTM E 84: Standard Test Method for Surface Burning Characteristics of Building Materials.
- 2. ASTM E 162: Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.
- 3. ASTM E 662: Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials.
- 4. AWI: Architectural Woodwork Institute.
- 5. AWS: Architectural Woodwork Standards.
- 6. FSC: Forest Stewardship Council.
- 7. IMO: International Maritime Organization.
- 8. IMO FTP: International Code for Application of Fire Test Procedures.
- 9. IMO FTP Code Part 2: Smoke and Density Test.
- 10. IMO FTP Code Part 5: Test for Surface Flammability.
- 11. ISO: International Organization for Standardization.
- 12. ISO 9001: Quality Management Systems.
- 13. ISO 14001: Environmental Management Systems.
- 14. KCMA A161.1: Performance & Construction Standard for Kitchen and Vanity Cabinets.
- 15. LEED: Leadership in Energy and Environmental Design.
- 16. NEMA LD-3: High Pressure Decorative Laminates.
- 17. NFPA 101: Life Safety Code.
- 18. NSF 35: High Pressure Decorative Laminates for Surfacing Food Service Equipment.
- 19. OHSAS: Occupational Health and Safety Assessment Series.
- 20. OHSAS 18001: Occupational Health and Safety Management Systems.
- 21. SCAQMD Rule 1168: Adhesive and Sealant Applications.
- 22. SCS: SCS Global Services.
- 23. UL 723: Test for Surface Burning Characteristics of Building Materials.
- 24. UL 2818: GREENGUARD Certification Program for Chemical Emissions for Building Materials, Finishes and Furnishings.
- A. Reference Standards:
- 1.04 SUBMITTALS
- A. Submit under provisions of Section 01 3000 - Submittals.
- B. Product Data: Submit the following:
- 1. Product data for each specified product. Include manufacturer’s technical data sheets and published instruction instructions.
- 2. Safety Data Sheets (SDS).
- C. Shop Drawings: Fully dimensioned shop drawings showing layouts and components, including edge conditions, joinery, terminating conditions, substrate construction, and cutouts and holes. Include elevations, section details, and large scale details. ...
- D. Samples: Selection and verification samples for each color, pattern, and finish required.
- E. Quality Assurance Submittals:
- 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties, if required.
- 2. LEED Submittals: Applicable LEED documentation for potential credits specified in this Section.
- 1.05 REGULATORY REQUIREMENTS
- 1.06 QUALITY ASSURANCE
- A. Qualifications:
- 1. Manufacturer Qualifications: Manufacturer producing products in an ISO 9001, ISO 14001, and OHSAS 18001 certified facility.
- 2. Fabricator Qualifications: Minimum of three years documented experience in fabricating decorative plastic laminates similar in scope and complexity of this Project.
- 3. Installer Qualifications: Minimum of three years documented installation experience for projects similar in scope and complexity to this Project. [Installer shall be the fabricator].
- B. LEED 2009 rating system potential credits for plastic laminate:
- 1. [LEED-NC] [LEED-CI] MR Credit 4 - Recycled Content.
- 2. [LEED-NC] [LEED-CI] MR Credit 5 - Regional Materials.
- 3. [LEED-NC] [LEED-CI] MR Credit 6 - Rapidly Renewable Content.
- 4. [LEED-NC] [LEED-CI] MR Credit 7 - Certified Wood.
- 5. [LEED-NC] [LEED-CI] IEQ Credit 4.4 - Low-Emitting Materials - Composite Wood and Agrifiber Products.
- 6. LEED-CI IEQ Credit 4.5 - Low-Emitting Materials, Systems Furniture and Seating.
- C. LEED 2009 rating system potential credits for Wilsonart® Adhesives:
- 1. [LEED-NC] [LEED-CI] IEQ Credit 3.2 - Construction Indoor Air Quality Management Plan - Before Occupancy.
- 2. [LEED-NC] [LEED-CI] IEQ Credit 4.1- Low Emitting Materials - Adhesives and Sealants.
- 3. [LEED-NC] [LEED-CI] IEQ Credit 4.4 Low-Emitting Materials - Composite Wood and Agrifiber Products.
- 4. LEED-CI IEQ Credit 4.5 - Low-Emitting Materials, Systems Furniture and Seating.
- D. Mock-Up:
- 1. Install at Project site using acceptable products and manufacturer approved installation methods. Obtain Architect’s acceptance for color, pattern, finish, fabrication, and installation standards.
- 2. Mock-Up Size: [____________] by [____________].
- 3. Mock-Up Size: Indicated on Drawings.
- 4. Mock-Up Location: [Indicated on Drawings] [As directed by Architect].
- 5. Maintain mock-up during construction for fabrication and installation comparison. If required, remove and legally dispose of mock-up when no longer required.
- 6. Incorporation: If permitted by Architect, mock-up may be incorporated into as part of the completed Work.
- 1.07 DELIVERY, STORAGE, AND HANDLING
- 1.08 PROJECT CONDITIONS
- A. Environmental Requirements: Ensure appropriate acclimatization between plastic laminate and substrate prior to fabrication. Condition plastic laminate and substrate surfaces in the same environment for 48 hours prior to fabrication. Condition at ap...
- 1. Adhesive: For best results, apply adhesives at temperatures at or above 65 deg F (18 deg F).
- B. Field Measurements: Verify actual measurements and openings by field measurements before fabrication; show recorded measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid constructi...
- 1.01 SECTION INCLUDES
- EDITING NOTE: Revise listing to suit Project requirements.
- EDITING NOTE: Section listings below are common references and based on the broadly accepted CSI MasterFormat® for Section numbers and titles. Revise to suit requirements for particular project.
- EDITING NOTE: Section listings below are common references. Revise to suit requirements for particular project.
- EDITING NOTE: Revise Reference Standards to suit Project requirements.
- EDITING NOTE: Following two LEED paragraphs list potential credits according to LEED 2009 for New Construction & Major Renovations (LEED-NC) and LEED 2009 for Commercial Interiors (LEED-CI). Coordinate with designated Project LEED AP for credits app...
- PART 2 - PRODUCTS
- 2.01 MANUFACTURER
- A. Basis of Design: Wilsonart.
- 2.02 LAMINATE PROPERTIES
- A. Laminate Composition: Decorative surface papers impregnated with melamine resins and pressed over kraft paper core sheets impregnated with phenolic resin. Sheets then bonded together under pressures greater than 1,000 lbs. per sq. in. and high temp...
- B. Sustainable Design Conformance Standards:
- 1. UL 2818 GREENGUARD Gold Certified.
- 2. SCS Certified Indoor Air Quality Advantage™ Gold Certified.
- 3. SCS Chain of Custody Certified for FSC® Mix, FSC Controlled Wood.
- 4. SCS Recycled Content Certified.
- C. Surface Burning Characteristics:
- 1. Test Standards: ASTM E 84, ASTM E 162, ASTM E 662, IMO FTP Code Part 2
- and Part 5, and UL 723.
- 2. Interior Finish Classification, Fire-Rated Laminate: Class A according to NFPA 101. Flame spread less than 25 and Smoke Developed less than 450.
- D. Surfaces Subject to Food Contact: Comply with NSF Standard 35.
- 2.03 STANDARD DECORATIVE LAMINATES
- 2.14 PHENOLIC BACKER SHEETS
- WILSONART CONTACT INFORMATION: Wilsonart, 2400 Wilson Place, Temple, TX 76503-6110. Tel. 254.207.7000, Toll-Free 800.433.3222, Fax 254.207.3209.
- Website: www.wilsonart.com
Guide Specification
EDITING NOTE: If color, pattern, and finish not specified above, delete and select
one of the following options.
EDITING NOTE: If color, pattern, and finish are not specified in the subparagraph
above, delete and select one of the following subparagraphs.
4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section.
5. Color, Pattern, and Finish: Indicated on Drawings.
6. Color, Pattern, and Finish: Selected from manufacturer's full range of available
selections.
2.07 VIRTUAL DESIGN LIBRARY (VDL) LAMINATES
A. Product: “Wilsonart
®
Virtual Design Library Laminate.”
B. Enhanced Laminate Performance: Laminate with AEON™ Enhanced Performance
Technology for increased surface wear resistance and surface abrasion performance.
C. Vertical Surface Type: [“Wilsonart Type 362”] [“Wilsonart Type 367”].
1. Sheet Thickness: 0.028 inch nominal.
2. Laminate Conformance Standard: NEMA LD 3, Grade VGP.
3. Color, Pattern, and Finish: [_________________________].
4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section.
5. Color, Pattern, and Finish: Indicated on Drawings.
6. Color, Pattern, and Finish: Selected from manufacturer’s full range of available
selections.
D. Postforming Type: [“Wilsonart Type 372”] [“Wilsonart Type 377”].
1. Sheet Thickness: 0.039 inch nominal.
2. Laminate Conformance Standard: NEMA LD 3, Grade HGP.
3. Color, Pattern, and Finish: [_________________________].
4. Color, Pattern, and Finish: Specified in SCHEDULE Article of this Section.
5. Color, Pattern, and Finish: Indicated on Drawings.
6. Color, Pattern, and Finish: Selected from manufacturer's full range of available
selections.
2.08 [MARKERBOARD] [AND] [CHALKBOARD] LAMINATES
A. Markerboard Product: Wilsonart
®
Markerboard Laminate.
EDITING NOTE: Select type(s) required for Project.
EDITING NOTE: Not all finishes are available with AEON™ Enhanced Performance
Technology. If AEON™ not required, delete the following paragraph.
EDITING NOTE: Reach beyond the wallboard with Wilsonart’s Virtual Design Library.
Wilsonart understands that design should not be limited by pegs on a board, links in a chain,
or space on a shelf. From photorealistic imagery to abstract and artistic graphics, our online
Virtual Design Library offers a growing selection of exclusive laminate patterns to fit your
needs. This ever-growing collection offers hundreds of additional designs online.
Section 06 0620 - 9
Decorative Plastic Laminate