User Manual

2 The WIMAN Command Line Level
18 / 90
The user-defined hopping pattern must be switched on with
FtabMode set to USER.
Authorization Level: 2
Preset value: System
Scope: System, User
The parameter LoopData sets the hexadecimal value to be sent
in a LoopTest.
Authorization Level: 2
Preset value: FFFFFFFF
Scope: 00000000 … FFFFFFFF
The parameter LoopMode determines, which bit pattern and
frame lengths are to be used with the independent back loop test
(see loop test below). This parameter is not available on STAR
devices.
It is possible to set the values normal, load, long and high. The
values function as follows:
Normal
Pseudo coincidental data is transmitted. All 256 byte values
occur equivalently. A break is inserted between two pack-
ages. This type of test is to simulate the "normal" data
communication in a network.
Load
Pseudo coincidental data is transmitted. However, in this
type of test it is transmitted with highest possible transfer
rate.
Long
“Stress” data (bit pattern, which lead to a high utilization) is
transmitted at a normal transfer rate.
High
“Stress” data is transmitted with high transfer rate.
Attention:
If the looptest is executed in an operating radio net, all values
except normal should be avoided for the parameter LoopMode.
Use of any other value may result in malfunction.
Authorization Level: 2
Preset value: long
Scope: normal, load, long, high
LoopMode
FTabMode
LoopData