User Manual
2 The WIMAN Command Line Level
25 / 90l
Scope: valid IP-address
2.5.5 Other Parameter
The parameter PS1 determines the appearance of the WIMAN
command line prompt. The factory-installed setting is
WIMAN II >. However, the user has the option to edit the
command line prompt (e.g. DEVICE 1:).
Authorization Level: 2
The parameter SyncMode determines whether the WIMAN gen-
erates the Burst-synchronizing signal (master), or if it will re-
ceive an externally generated Burst signal (Slave). Further de-
tails to this parameter can be found in chapter 4.5 on page 53
Authorization Level: 2
Preset value: Off
Scope: Off, Master, Slave
2.6 Instructions
Issuing instructions on the command line level configure the
WIMAN radio modem. The instructions available for use de-
pend on the authorization level and the operating mode.
The instructions can be roughly divided into three categories:
• Instructions for the manipulation of passwords and authori-
zation levels
• Instructions for manipulating and transferring configuration
data
• General instructions
2.6.1 Instructions for the manipulation of Passwords and
Authorization Levels
The following commands are available for the designation and
modification of passwords:
Note
To execute instructions the device must be in configuration
mode (see Chapter 3, page 33)
The instruction Passwd console permits the definition of a
password for access to the first authorization level (console).
Passwd console
SyncMode
PS 1