Specification

TECHNICAL GUIDE
95.0% AFUE STANDARD ECM SINGLE
STAGE MULTI-POSITION RESIDENTIAL
GAS FURNACES
MODELS: TM9E
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential
applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
1104781-BTG-F-0618
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV, National Fuel Gas Code and may
be vented either through side wall or roof applications using
approved plastic combustion air and vent piping. Approved
plastic combustion air and vent piping include Selkirk Polyflue,
Duravent Polypro, & Centrotherm Innoflue polypropylene vent-
ing systems.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable opera-
tion.
Low unit amp requirement for easy replacement applica-
tion.
All models are convertible to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
5 speed, direct drive Standard ECM style high efficiency
DC motor.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
Timed on, adjustable off blower capability for maximum
comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at duct per-
formance testing
conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Protection included from air intake, exhaust vent, or con-
densate blockage.
Patent pending self priming internal condensate trap
design for easy installation.
Venting applications - may be installed as a either 2-pipe
(sealed combustion) or single-pipe vent (using indoor com-
bustion air.
No special vent termination required.
1/4 turn knobs provided for easy door removal.
High-efficiency blower motor for lower electrical power
usage and improved A/C SEER ratings.
Insulated blower compartment for terminal and acoustic
performance.