Specifications

Generator Data
Generator Type (4) RFL
Voltage Regulation +/- 5%
Frequency Regulation +/- 3%
Harmonic Distortion < 5%
Motor Starting Ability (5) 7.5 hp
Size and Weight
L x W x H (in) 44.1 x 33.2 x 38.1
Ship Weight (lbs) 725 lbs.
Warranty Information
Engine/Generator 2 Years/1 Year
Optional Accessories
Engine Heater
Vapor Fuel Filter
ULATS165 Auto Transfer Switch (sold separately)
Engine Start Delay 3 Seconds
Transfer Delay 15 Seconds
Retransfer Delay 5 Minutes
Engine Cooldown Delay 1 Minute
14-Day Exercise Circuit Standard
Warranty 1 Year
Engine Specifications
Make/Model B&S Vanguard
Displacement/Type 895 c.c./OHV
Engine Speed 3600 rpm
Engine Features
Electronic Ignition Standard
Cooling System Air
NG or LP Vapor Fuel System Standard
Critical Grade Exhaust System Standard
DBA Rating @ 7 meters (23 ft) 67 N-L/72.5 F-L
Battery Rack/Cables (3) Standard
Vibration Isolators Standard
Low Oil Protection Standard
Float Battery Charger Standard
Fuel Consumption (estimate)
Full Load - LP Gas (2) 2.96 gal/hr
Half Load - LP Gas (2) 1.75 gal/hr
Full Load - Natural Gas 260 ft
3
/hr
Half Load - Natural Gas 170 ft
3
/hr
Required Fuel Pressure 4-6 oz or 7-11” w.c.
225 South Cordova Ave
Le Center MN 56057
East Coast: (800) 733-2112
West Coast & Canada: (800) 324-8174
E-Mail: wincosales@wincogen.com
Web Site: www.wincogen.com
NOTES:
(1) Derate 3.5% per 1,000 feet elevation above sea level
(2) One gallon of L.P. gas equals 4.23 lbs
(3) Battery not included. Requires 12-volt Group 26, 450 cca battery
(4) Rotating Field Brushless design generator
(5) Code G capacitor start motor
PSS15B
PSS15B 04/08
Packaged Standby Generator
POWER RATING– CONTINUOUS STANDBY (1)
MODEL POWER L.P. Gas Natural Gas
NUMBER OUTPUT (60hz) KW KVA AMPS KW KVA AMPS
PSS15B 120/240V, 1-Phase, 1.0 p.f. 15 15.0 60.0 12 12.0 50.0
FEATURES
Easily installed outside new or existing homes
Critical grade exhaust system for quieter operation
Mainline circuit breaker included standard
Sound attenuated housing constructed of galvannealed
steel with durable powder paint finish & hinged access doors
Equipped for either Natural Gas or LP Vapor fuel
CARB & EPA approved
UL & CSA approved
Low maintenance
Requires purchase of a transfer switch for automatic
operation (sold separately - see specs below)
Starting System
PSS15B4W 4-Wire Start System
Requires purchase of an ASCO165 4-wire start
transfer switch. All starting controls including start
contacts and fuel solenoid contacts as well as all delays
are located on the control board in the ASCO transfer
switch. Cycle cranking is included standard. A Running
Time Meter, Off/Normal & Auto/Run/Start Switches are
provided on the generator control panel.
PSS15B2W 2-Wire Start System
Requires purchase of the optional 2 -wire start control
which makes the unit compatible with any transfer switch
using a dry contact closure upon power failure. Two wire
start controls come standard with a 10 second start delay
and 90 second cooldown delay. Cycle cranking is included
standard. Running Time Meter & Auto/Off/Run Switch are
provided on the generator control panel.