User`s guide

I cannot feel any floor suction for the circulation pump.
The circulation pump in your spa will pull almost all of its water through the filter and not the floor suction.
The floor suction for that pump is only in place as a relief suction point in case something gets caught in the
filter area.
My jets shut off on their own while the spa is in use.
There are two possible reasons why your jets are shutting down while in use. The first and most common
reason is because they are designed to do so after twenty minutes. They do this in case you walk away from
the spa and forget to turn them off yourself. If you left them running all the way until the spas next use it
would add up on your power bill very quickly. You will no if it is the programmed shut off time if the jets can
be turned right back on after shutting off. If they can not be turned right back on then their thermal protec-
tion has shut them down. If the pumps trigger the thermal protection it means that there is too much ambient
heat stored up in the equipment area. This can happen in the warmer months because the spas insulation
system acts kind of like a thermos. To relieve this symptom you can remove the foam insulation from behind
the equipment panel during the warmer season, (see Panels in Other Components section of the on-line com-
prehensive version of this manual). Just be sure to replace the insulation panels before the winter months so as
to conserve energy costs for operating your spa.
My jets come right back on after I try to turn them off.
If the Cleanup Mode button has been pushed then the pumps will run at high speed for one minute. Often
users of the spa might accidentally hit the cleanup mode on their way in or out of the spa, or sometimes you
may hit the wrong button trying to adjust the light or jets. If when turning the jets off they keep coming back
on, try hitting the Cleanup Mode button to turn them off.
I am getting a strange reading on my LCD display screen.
The Spaside Control on your spa will tell you if certain errors are detected. There are three error messages
you may encounter.
17
Trouble Shooting
OH Overheat Protection (spa is deactivated)
DO NOT ENTER THE WATER. If the spa water has reached 112 degrees Fahrenheit, remove the spa
cover to cool the water. On a Fitness Series models an overheat may occur if the filter cycle is set too
long during hot parts of the day. At 110 degrees Fahrenheit the spa should reset itself. If the high-
limit sensor detects 118 degrees Fahrenheit at the heater the spa will be shut down. When the heater
cools to 110 degrees Fahrenheit press any button to reset the spa. If the spa will not reset shut down
power to the spa, and call Wind River Spas service department.
FL (Not Flashing)
The pressure switch in your spa is malfunctioning. Call Wind River Spas service department.
SN (spa is deactivated)
A temperature sensor is malfunctioning. Call Wind River Spas service department.