2.5 Filling the reserve supply container
2.5.1 VarioWIN Exklusiv-S – Manual filling
Fold open the cover of the reserve supply container (Fig. 8) and fill the reserve supply container up to max. 1
cm below the edge. Close the cover.
Tip:
The reserve supply container should always be completely filled with pellets. This allows the incoming pel-
lets to drop into the container better, reduces the size of the conical part of the pile and means that the contai-
ner empties better.
Fig. 8 Folding open the cover
When filling, make sure no extraneous materials (e.g. shreds of the pellet bags resulting from cutting
open the bags) get into the reserve supply container – they could block the rotary feeder!
2.5.2 VarioWIN Exklusiv-P – Pneumatic pellet feed
The reserve supply container is filled by the fully automatic pellet feed. WINDHAGER Customer Service or the
customer service PARTNER will perform the first fill (start-up), take the boiler and its pellet supply into service
and familiarise the customer with the operation and cleaning of the boiler, with reference to the Operating Manu-
al.
Operation
2.5.3 VarioWIN Premium/Exklusiv-D – Direct pellet feed
The VarioWIN is supplied by the direct pellet feed from the year-round pellet reserve supply container. WIND-
HAGER Customer Service or the customer service PARTNER will perform the first fill (start-up), take the boiler
and its pellet supply into service and familiarise the customer with the operation and cleaning of the boiler,
with reference to the Operating Manual.