Specifications
13
5s
RESET
Full-text display
(illuminated display)
Manual operation / flue cleaning
function
Signal lamp (LED)
„Operation“ – green;
„Malfunction“ – red
Menu buttons
ON/OFF button
Menu line
Operating phases are
displayed here, including
Standby, Burner OFF, etc.
Assignment of buttons to
their specific function
Operation
The various operating modes are displayed on InfoWIN together with the corresponding operating phases.
The following operating modes exist:
–OFF
– ON (with self-test, lighting ON, lighting OFF)
– Pellet feed
– Solid fuel / buffer mode
– Manual operation
– Flue cleaning function
– Shutdown procedure
Corresponding operating phases:
– Standby
– Purging
– Ignition phase
– Flame stabilisation
– Modulation mode
– Burnout
– Burner OFF
– Switch off heat generator
è
Boiler temperature
Standby
Info Menu
38
°C
Fig. 9 InfoWIN
2.6 InfoWIN
The InfoWIN is the boiler’s display and operating unit.
The InfoWIN unit consists of a large text display, an ON/OFF button with an LED signal lamp indicating Opera-
tion (green) or Malfunction (red); a switch for the flue cleaning function and four individual menu buttons. The
function of each menu button is displayed on the Menu line.