Specifications
29
Burning duration with 25 kg pellets
VarioWIN Burning duration at nominal output
VAE 120 P approx. 10 h
5s
RESET
5s
RESET
5s
RESET
5s
RESET
The factory setting for „Feed operating mode“ is „switched off“.
Without time control: Select this if the feed noise (suction turbine)
is not audible or intrusive in the living area (or adjacent premi-
ses). This mode guarantees the fewest possible feeds because
the reserve supply container is always „run to empty“.
Functional description: The pellet feed is automatically switched
on if required at any time.
With start time: Select this if you want the feed to start at the same
time every day.
Functional description: The reserve supply container is filled
every day if required at the set time (see page 31). Interim fills
are also performed if the filling amount is not sufficient for 24
hours.
With enable time: Select this if the feed noise (suction turbine) is
audible or intrusive in the living area (or adjacent premises).
Functional description: The pellet feed is enabled during a time
period that can be set (see page 32) and is automatically star-
ted at this time if required. The reserve supply container is fully
refilled at the end of the enable time, if required.
Tip: A complete fill sucks in about 25 kg of pellets. Even if more
pellets are required during the blocked time, there is no automatic
fill and the VarioWIN switches off (fault message 381). Therefore,
do not select a lock-out time that is too long.
Fig. 74
Operation
Fig. 75
Fig. 77
It is only ever possible to select one menu item at a time. The
„Time profile feed“ corresponding to this selected menu item
can then be set in section 2.10.1.4.
Fig. 76
Use the
arrow
buttons to select the required sub-menu item – Fig. 74.
Save the changed feed operating mode by pressing the
Yes
button –
Fig. 75. The display shows „Parameter is saved“ for a few seconds
(Fig. 76) and then changes back to the previous level – Fig. 77.
The menu item or sub-menu item is exited by pressing the
Back
but-
ton (Fig. 77) or after a delay of 45 seconds.
Feed operating mode
with enable time
with start time
without time control
switched off
Save
Yes No
Feed operating mode
with enable time
with start time
without time control
switched off
Save
Yes No
Parameter is
saved
.....
(Animated symbol)
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Time profile ash comp.
Choose Back