Specifications
44
Tip: Position newspaper or the like to protect the floor against fly ash before opening the combustion chamber
door.
– Open the cladding door and ash door, empty the ash pan under the combustion chamber and the ash pan
for the heating surfaces – Fig. 125.
Assembly:
– Push in the ash pans, close the doors.
– Switch the VarioWIN back on with the ON/OFF button.
Fig. 123 Connect the key and operate it
Fig. 124 Switching off the VarioWIN Fig. 125 Emptying the ash pan
Always switch the boiler off first with the ON/OFF button (Fig. 124) and wait until burnout mode has
finished. Do not open the combustion chamber and ash door during operation.
3.5 Ash pan, ash on heating surface
Care, cleaning and maintenance
3.4 Heating surfaces
VarioWIN Premium
Optimum efficiency is achieved when the heating surfaces are cleaned as often as possible using the key. Howe-
ver, no later than before the ash pan is emptied or ash is removed from the heating surfaces, the key should
be connected on the right-hand side and moved back and forth several times – Fig. 123.
Ash pan for
heating surfaces
When emptying the ash pans, remember that there could still be embers in the ash!
VarioWIN Exklusiv
The heating surfaces are cleaned fully automatically after the set start times (see section 2.10.1.6) and when
approx. 15 kg of fuel has been consumed ⇒ on average 1x a day.
Ash pan for
combustion chamber