User's Manual

Confidential Page 9 8/26/2004
2210 O’Toole Ave. #200, San Jose, Ca. 95131
Tel: 408-576-1770 Fax: 408-576-1790
7. Key parameters settings
Here lists all the parameters preset to Windigo Headset module, and also
please be noted that these parameters can be customized based on
customers preference.
A. Buttons numbers: 3
B. Long press timer: 1 second
C. LED on time: 20 ms
D. LED quick flash interval: 200 ms
E. LED flash interval: 1 second
F. LED quick flash times for standby: 1
G. LED quick flash times for standby with ACL: 1
H. LED quick flash times for connecting: 2
I. LED quick flash times for talking: 4
J. LED quick flash times for ON/OFF: 5
K. LED flash interval for paring: 128 ms
L. Threshold for high voltage alert: 3.55 V
M. Threshold for low battery alert: 3.50 V
N. Threshold for turning off headset: 2.80 V
O. Battery monitor interval: 32 seconds
P. Connecting mode timeout: 10 seconds
Q. Default audio input gain: 29
R. Default audio output gain: 10
S. Default pin code: 0000
T. Default headset name: BTHS03
U. Pairing mode timeout: 60 seconds