SDS
1620126 - Windmill Refrigerant
Revision Date 09-Feb-2021
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page 3 / 9
registry #)
Methylene fluoride
75-10-5
100
-
-
4. FIRST AID MEASURES
Description of first aid measures
Inhalation
Remove to fresh air.
Eye contact
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids.
Consult a physician.
Skin contact
In case of contact with liquefied gas, thaw frosted parts with lukewarm water.
Ingestion
Clean mouth with water and drink afterwards plenty of water.
Most important symptoms and effects, both acute and delayed
Symptoms
No information available.
Indication of any immediate medical attention and special treatment needed
Note to physicians
Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
Use extinguishing measures that are appropriate to local circumstances and the
surrounding environment.
Large Fire
CAUTION: Use of water spray when fighting fire may be inefficient.
Unsuitable extinguishing media
DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED.
Specific hazards arising from the
chemical
Cylinders may rupture under extreme heat. Damaged cylinders should be handled only by
specialists. Containers may explode when heated. Ruptured cylinders may rocket.
Hazardous Combustion Products
Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact
Yes.
Sensitivity to Static Discharge
Yes.
Special protective equipment for
fire-fighters
Firefighters should wear self-contained breathing apparatus and full firefighting turnout
gear. Use personal protection equipment.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area).
Take precautionary measures against static discharges. Contents under pressure. Empty
containers pose a potential fire and explosion hazard. Do not cut, puncture of weld