Machine Data Label This carpet extractor is an electrical powered, portable carpet extractor intended for commercial use. The appliance sprays a cleaning solution onto the carpet agitates the wet carpet, and then extracts the soiled solution back into the unit's recovery tank. The appliance is fitted with and a hand tool for cleaning upholstery and stairs. Warranty Registration Thank you for purchasing a Kärcher North America product. Warranty registration is quick and easy.
Table of Contents Machine Data Label . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 How To Use This Manual . . . . . . . . . . . . . . . . . . . . . 4 Safety IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . 5 HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . . 7 Safety Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Grounding Instructions . . . . . . . . . . . . . . . . . . . . . .
How To Use This Manual This manual contains the following sections: • • • • • How to Use This Manual Safety Operations Maintenance Suggested Spare Parts The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death. The OPERATIONS section is to familiarize the operator with the operation and function of the machine.
Safety IMPORTANT SAFETY INSTRUCTIONS When using this machine, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Use only indoors. Do not use outdoors or expose to rain.
Safety IMPORTANTES MESURES DE SÉCURITÉ L’utilisation d’un appareil électrique demande certaines précautions: LIRE TOUTES LES INSTRUCTIONS AVANT DE FAIRE FONCTIONNER (CET APPAREIL). Pour réduire les risques d’incendie, de choc électrique ou de blessure: Cet appareil ne doit être connecter qu a des prises ayant une sortie de terre. Ne pas laisser l’appareil sans surveillance lorsqu’il est branché. Débrancher lorsque l’appareil n’est pas utilisé et avant l’entretien.
Safety The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
Safety Les symboles ci-dessous sont utilisés à travers ce manuel comme illustré dans leurs descriptions : DEGRÉS DE RISQUES EN CAS DE DANGER Il existe trois degrés de risques identifiés par les termes signalétiques –AVERTISSEMENT et ATTENTION et POUR VOTRE SÉCURITÉ. Le degré de risque est défini de la manière suivante : AVERTISSEMENT - Dangers ou méthodes dangereuses qui POURRAIENT provoquer de graves blessures ou entraîner la mort.
Safety Safety Labels These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them. EMPLACEMENT DE L'ÉTIQUETTE DE SÉCURITÉ REMARQUE : Ces dessins indiquent l'emplacement des étiquettes de sécurité sur la machine. Si, à tout moment, les étiquettes deviennent illisibles, contactez votre représentant autorisé pour un remplacement rapide.
Safety THIS PRODUCT IS FOR COMMERCIAL USE ONLY. Proper Grounding Grounding Pin Electrical In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit.The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors. Grounding Instructions Metal Screw Adaptor FIGURE B Tab for Grounding Screw This appliance must be grounded.
Notes 86401310 Operators Manual - ADM8 115V 11
Operations Technical Specifications ITEM Height DIMENSION / CAPACITY 42” (107 cm) Length 35” (89 cm) Width 18.5” (47 cm) Weight 92 lbs (42 kg) Wheels (2) 10” dia. (25 cm) wheels by 2” Vacuum Shoe 17” (43.18 cm) cast aluminum with spring loaded down pressure Solution Spray 2 quick change jets Power Cable 50’ (12.7 m) (14 gauge) Electrical 115V, 15 A, 60 Hz Electric Vacuum Motor (1) - 3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift - 117” (297 cm) Brush (1) 15” (38.
Operations 42” (107cm) 35” (89cm) 18.5” (47cm) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Operations 8 9 4 Controls 5 6 1. Main Handle. Used to pull and maneuver machine 2. Handle Adjustment. Used to adjust height of handle 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets. Intermittent position (up) requires operator to depress 1 of 3 trigger switches to dispense solution. Center position is off. 7 5. Brush Motor Switch. Turns on brush motor 6. Vacuum Motor Switch. Turns on vacuum motor.
Operations Components 11 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 1 3. Brush Height Adjustment. Used to regulate brush height from storage position to various carpet heights. 4. Recovery Tank. Used to collect dirty cleaning solution. 10 3 2 9 5. Solution Tank. Used to hold cleaning solution. 6. Recovery Tank Dome. 7. Vacuum Shoe. 8. Brush Housing. 9. Front Lifting Handle.
Operations Components 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off 4. Clean-Out Opening. 5. Pour Spout. 6.
Operations FILL LINE Filling the Admiral NOTE: Use clean bucket of water to fill solution tank. Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank. Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before replacing recovery tank.
Operations Filling the Admiral - continued 1. Remove electrical cord and literature from recovery tank. 2. Remove the recovery tank from the machine. 3. Fill the Solution Tank with 8 gallons (30.3 ltr.) of water, that is no more than 140°F/60°C. 4. Add 8-16 oz. (237ml-473ml) of cleaning chemical.
Operations 5. Replace the Recovery Tank on the machine. Machine Operation 1. Plug cord into grounded outlet. NOTE: Be sure dome is seated on recovery tank, and float shut-off is installed correctly. 2. Adjust brush to proper setting. NOTE: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to motor or carpet. 3. Turn on brush and vacuum motor switches ("ON"="I").
Operations 4. Adjust handle to comfortable operating position. Tip machine back by main handle to move to starting point. 5. Lower machine to floor. 6. Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray. The intermittent setting requires the operator to hold any one of the three trigger switches in the "on" position with the fingers, and is typically used in small areas where short cleaning passes are made.
Operations 2. Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. 1ft. (30cm) 3. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush contact area approximately 1 inch. 4. During operation, observe the following: The Admiral is equipped with clear internal covers to facilitate operator viewing of dirty solution and vacuum air flow.
Operations 6. After cleaning, turn off all controls, return brush to storage position and carefully unplug machine. 7. To speed drying, use an air moving fan. 8. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Drain solution tank after each use.
Operations Accessory Tool Usage Use only one of the following acceptable accessory tools. 8.600-061.0 - STANDARD WAND 8.600-060.0 - DELUXE PROFESSIONAL WAND 8.603-154.0 - HOSE ASM, CST HANDTOOL 1. Pull back collar and insert over machine mounted fitting, then release collar to lock into place. 2. Lift door on front of vacuum shoe and insert 1 1 /2 inch hose cuff into hole. 3. Turn on vacuum motor switch and set solution switch to intermittent position.
Maintenance Service Schedule MAINTENANCE Check machine for cord damage Check recovery dome and gasket for damage and cleanliness Check brush - should be clean with no lint or strings attached Inspect vac shoe for blockage; remove fibers with coat hanger, etc.
Maintenance Periodic Maintenance Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry. 8. Check cooling air screen (located on frame behind left wheel) for lint or debris. 9. Check float and shut-off screen and clean as necessary.
Maintenance Vacuum Motor Replacement Only qualified maintenance personnel are to perform the following repairs. Seul le personnel d'entretien qualifié peut effectuer des réparations. WARNING: The green ground wire must be attached for safe operation. See wiring diagram. AVERTISSEMENT: Le fil à la terre vert doit être attaché pour un fonctionnement en toute sécurité. voir le schéma de câblage. End Cap Carbon Brushes 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3.
Maintenance Belt Replacement Only qualified maintenance personnel are to perform the following repairs. SIDE PLATE Seul le personnel d'entretien qualifié peut effectuer des réparations. 1. Turn off all switches and unplug machine. 2. Remove recovery tank and brush. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt.
Maintenance Solution Pump Replacement Only qualified maintenance personnel are to perform the following repairs. Seul le personnel d'entretien qualifié peut effectuer des réparations 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses from fittings in pump. 5. Remove the (2) screws that fasten the pump to the frame. 6.
Maintenance Troubleshooting Chart PROBLEM No Power, Nothing Runs Vacuum Motor Will Not Run CAUSE Is the cord plugged in. Circuit breaker tripped in building. Faulty switch. Faulty power cord or pigtail. Plug in cord. Reset breaker. Call for service. Call for service. Vacuum circuit breaker tripped. Reset breaker. Faulty main vacuum switch. Loose wiring. Faulty vac motor. Call for service. Call for service. Call for service. See "Brush Replacement" in maintenance section. Remove debris from vac shoe.
Suggested Spare Parts PART NO. 86001140 86001100 86004570 86004580 86003630 86003330 86007970 86135320 30 DESCRIPTION BRUSH, ASM, 15 IN BELT, 180J6 MICRO-V JET BODY, MINI PROMAX BODY JET, MINI PROMAX 9504 FLOAT, SHUT-OFF DOME ASM, CLP FAM STRAINER, 3/8 IN.