Carpet Extractor Operating Instructions
MAINTENANCE 
86038280 04/04/07 
4-2ENG 
 SOLUTION PUMP REPLACEMENT 
1.   Turn off all switches and unplug the machine. 
2.   Remove recovery tank. 
3.   Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside 
of the frame. 
4.   Remove solution hoses from fittings in pump. 
5.   Remove the (2) screws that fasten the pump to the frame. 
6.   Reverse process to install pump. 
     ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE 
    FOLLOWING REPAIRS. 
BELT REPLACEMENT 
1.  Turn off all switches and unplug machine. 
2.  Remove recovery tank and brush. 
3.  Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the 
frame. 
4.  Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt. 
5.  Remove the (2) screws that fasten the vacuum shoe links (86227350 - PRV NO. 05016) to the brush housing. 
6.  Remove the (3) screws that fasten the side plate (86249420 – PRV NO. 62759) to the brush housing to 
remove belt. NOTE: All components associated with driving the brush will come out with the side plate. 
7.  Reverse process to install belt. 
86249420 
PRV NO. 62759
86227350 
PRV NO. 05016 
Pressure Switch 
86161980 
PRV NO. 42-809332
Valve Asm 
 86258830 - PRV NO. 84161
Diaphram 
 86235100 - PRV NO. 29206
Pump Replacement Parts for Shurflo 100 psi (86026400 – PRV NO. 65254) 
Pump Head 
86251040 
PRV NO. 65187 
Motor 
 86247370 - PRV NO. 53246
Diaphragm 
86235120 - PRV NO. 29219
Pump Head 
86251090 – PRV NO. 65204
Valve Asm 
86258860 - PRV NO. 84166
Pump Replacement Parts for Flojet 100 psi 230v (86004770 – PRV NO. 47477)