Operating instructions
MAINTENANCE 
 SABER (QSC) 86037050 01/24/07 
4-2
CHECKING BATTERY SPECIFIC GRAVITY 
Use a hydrometer to check the battery specific 
gravity. 
CHECKING GRAVITY 
A. Hydrometer 
B. Battery 
NOTE: Do not take readings immediately after 
adding distilled water, if the water and acid are not 
thoroughly mixed, the reading may not be 
accurate. 
Check the hydrometer readings against this chart. 
SPECIFIC GRAVITY 
@ 80
°
 F (27
°
C) 
BATTERY CONDITION 
1.265 100% CHARGED 
1.225 75% CHARGED 
1.190 50% CHARGED 
1.155 25% CHARGED 
1.120 DISCHARGED 
NOTE: If the readings are taken when the battery 
electrolyte is any temperature other than 80°F 
(27°C), the reading must be temperature 
corrected. 
To find the corrected specific gravity reading 
when the temperature of the battery electrolyte is 
other than 80°F (27°): Add (+) to the specific 
gravity reading 0.004 (4 points), for each 10°F 
(6°C) above 80° (27°C). 
Subtract (-) from the specific reading 0.004 (4 
points), for each 10°F (6°C) below 80°F (27°C).
Battery Check 