Industries Carpet Cleaner User's Manual

TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Machine will not run
Circuit breaker tripped in
building.
Check and reset.
Power switch failure. Test switch for continuity and replace if necessary.
Tripped circuit breaker. Reset.
Faulty power cord. Replace.
Replace. CAUTION: To reduce the risk of electrical
Fuse in motor is blown.
shock, unplug the machine before opening fuse
holder. Fuse will only open under extreme
conditions. Investigate cause before replacing.
Electrical shock Equipment not grounded. Follow grounding instructions exactly.
Receptacle not grounded. Have an electrician inspect building’s wiring.
Ensure that the machine wiring matches the
Internal wiring problem
appropriate wiring diagram. Replace any wires or
components that are short-circuiting.
Repeated circuit
breaker tripping
Mechanical problem.
Higher amp draws indicate a mechanical problem,
find the problem before using the machine.
Faulty circuit breaker.
Test circuit for continuity. Replace circuit breaker if
necessary.
Excessive vibration Pad not centered. Re-center pad.
Damaged or unevenly Replace pad. Do not rest machine on pad when not
worn pad. in use.
Damaged pad driver. Replace.
Pad does not turn but
motor is running
Shear coupling has failed. Replace coupling.
STORM POLISHER 980100 03/08/03
2-6