www.windsterhood.com User’s Manual ISLAND SERIES WS-68N30SS WS-68N36SS WS-68N42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed for indoor residential use only. DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT. Please read this operation manual thoroughly before using your range hood. Store it in a safe location for when you need to reference it in the future.
TABLE OF CONTENTS 1 Table of Contents Safety Information .............................................................. 2 – 3 Content Checklist ..................................................................... 4 Measurements ........................................................................... 5 Preparation ................................................................................ 6 Installation ...........................................................................
2 SAFETY INFORMATION SAFETY INFORMATION TO REDUCE THE RISK OF A FIRE, ELECTRICAL SHOCK, AND/OR INJURY OBSERVE THE FOLLOWING: Unit is intended for indoor residential use only. If you should have questions, contact the manufacturer at the address or telephone number listed in the warranty. In case the unit should need to be cleaned or repaired, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
SAFETY INFORMATION 3 TO REDUCE THE RISK OF FIRE, OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. Regardless of heat level, never leave any surface materials unattended while operating an open flame. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). Depending on amount of usage, clean ventilating fans and filters frequently.
4 CONTENT CHECKLIST CONTENT CHECKLIST 1. CONTENTS INCLUDED a. (1) WS68-N series (30‖, 36‖ or 42‖) hood assembly b. (1) Lower duct cover (16-1/2‖) c. (1) upper duct cover (22-3/4‖) d. (1) User’s manual e. (1) 7‖ Damper transition adapter collar f. (1) Aluminum Filter (30‖ model) g. (2) Aluminum Filters (36‖/42‖ model) h. (1) Screw packet i. (1) Duct cover support bracket 2. CONTENTS NOT INCLUDED a. WS68-NLDC (Long duct cover) b. WS68-NSDC (Special duct cover) c.
MEASUREMENTS 5
6 PREPARATION PREPARATION 1. BEFORE YOU START **BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT** **DO NOT INSTALL IF DAMAGED** **RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED** a. Be sure you have all the content of your purchase and required tools for this installation. b. Installation may take at least 2 to 3 hours from start to finish. c. Plan to use as few elbows or turns as possible for more efficient air flow. d. Collar size may need to be increased if utilizing a long duct run. e.
INSTALLATION 7 INSTALLATION 1. STANDARD INSTALLATION a. Make sure all preparation steps are completed. b. Determine your ceiling height to see if you need an extension. i. Hood unit (with glass) height = 3-1/4‖ (30‖ model only) ii. iii. Hood unit (with glass) height = 4-1/4‖ (36‖ model only) Hood unit (with glass) height = 6‖ (42‖ model only) iv. Standard DC height = 16-1/2‖ (lower) + 22-7/8‖ (upper) v. Minimum height (Standard duct cover only) = 24-3/4‖ vi.
8 INSTALLATION 2. EXTENSION INSTALLATION (OPTIONAL) a. AFTER COMPLETING STEP A – D OF STANDARD INSTALLATION, replace the standard support frame and duct cover with either the extension set or the short duct cover set. b. REPEAT “STEP F – M” from STANDARD INSTALLATION. 3. COLD WEATHER INSTALLATION (OPTIONAL) a. Check with your local building codes to see if a CFM reducer is an acceptable alternative to make-up air. b. Remove the WS68-NCFMR (CFM Reducer) and inspect for any sign of defect or damage.
INSTALLATION DIAGRAM INSTALLATION DIAGRAM 9
CLEANING & MAINTENANCE 10 OPERATION & FEATURES 1. TOUCH SENSOR CONTROL SWITCH (from left to right) a. Sensor 1 – Dual purpose (Power / Delay Shut-off function 1 minute) b. Sensor 2 – Low Speed c. Sensor 3 – Medium Speed d. Sensor 4 – High Speed e. Sensor 5 – Light Switch Remark: During operation when press ―Sensor 1‖, then hood will automatically shut off after 1 minute. If want to avoid the countdown process, just press ―Sensor 1‖ again, the hood will stop immediately. 2. ALUMINUM FILTERS a.
CLEANING & MAINTENANCE 11 CLEANING & MAINTENANCE .WARNING!!!. To prevent the possibility of a fire and explosion, do not use flammable liquids or solvents to clean the unit or any of its parts. Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning. Please thoroughly clean the unit weekly as stainless steel can rust under certain condition or by improper cleaning. 1. RANGE HOOD a.
12 TROUBLESHOOTING TROUBLESHOOTING .WARNING!!!. Check to make sure all power sources are disconnected before starting any troubleshooting. Safety gloves and glasses should be worn when working on the unit. Serious injury or death may occur if safety precautions are not followed. WS-68N Series Light issue LED (All not turning on) 1. Locate and Replace defective Fixture (All Fixtures run on same circuit). 2. New Transformer/ Driver replacement may be required Speed Levels/Controls not working correctly 1.
WARRANTY / CONTACT/ US PART LIST / REPLACEMENT WIRING DIAGRAM PART LIST / REPLACEMENT # Description # Description 1 2 3 4 5 Chimney Supporting Frames Duct cover Hood body assembly LED lights Touch sensor control switch 6 7 8 9 10 Control Board Capacitor Transition collar Squirrel cage motor Aluminum filter WIRING DIAGRAM WARRANTY / CONTACT US 13
14 WARRANTY / CONTACT US WARRANTY / CONTACT US LIMITED WARRANTY Windster Hoods Inc. warrants its product against defects in material or workmanship as follows: Labor: For a period of one (1) year from the date of purchase, if the product is determined to be defective, Windster will attempt to repair the product, at its option, at no charge. After the warranty period, customer must pay for all labor charges. During the "labor" warranty period there will be no charge for any work done on the purchased model.