TROUBLESHOOTING 
12 
TROUBLESHOOTING 
WARNING!!! 
Check to make sure all power sources are disconnected 
before starting any troubleshooting. Safety gloves and glasses 
should be worn when working on the unit. Serious injury or death 
may occur if safety precautions are not followed. 
H Series 
Light Issue (All not 
turning on) 
1. Locate and Replace defective Fixture (All Fixtures 
run on same circuit) 
2. New Transformer replacement is required. 
LED light issue 
1. Check all wiring to and from the unit. 
2. LED may require new fixture or transformer. 
Lights Flickering 
1. Ensure wires are properly connected 
2. Replace light if defected. 
Burnt/melted control 
switch 
1. Complete Control switch replacement is required. 
Speed levels not 
working correctly 
1. Check all wiring to and from the unit. 
2. Complete control switch replacement is required. 
Unit lacking smoke 
intake 
1. Check ducting for foreign object. 
2. Ensure the ducting is properly sealed. 
3. Clean filters to increase airflow. 
Unit showing no power 
indication 
1. Make sure the power source is working properly. 
2. All wiring is connected. 
3. Check capacitor. 
Unit making humming 
noise 
1. Check ducting / dampers for proper installation. 
2. Replace defective capacitor with new one. 