User Manual
TROUBLESHOOTING
12
TROUBLESHOOTING
WARNING!!!
Check to make sure all power sources are disconnected
before starting any troubleshooting. Safety gloves and glasses
should be worn when working on the unit. Serious injury or death
may occur if safety precautions are not followed.
RA-30 Series
Halogen light issue
1. Replace burnt 35w Model GU10 light bulb.
Light Issue (One light
not turning on)
1. Replace old defective GU10 fixture with new
fixture.
Speed indicator not
showing speed levels
1. Complete Control switch replacement is required.
2. IC Board Replacement may be needed.
Burnt/melted control
switch
1. Complete Control switch replacement is required.
Speed levels not
working correctly
1. Check all wiring to and from the unit.
2. Complete control switch replacement is required.
3.IC Board Replacement may be needed
Unit lacking smoke
intake
1. Check ducting for foreign object.
2. Ensure that ducting is properly sealed.
3. Maintenance may be required to increase air-flow.
Unit showing no power
indication
1. Ensure 120v electrical power source is working
correctly.
2. IC Board Replacement may be required.
Unit making humming
noise/Motor not starting;/
LCD indicator displaying
speed levels.
1. Capacitor replacement is required.