www.windsterhood.com User's Manual WALL MOUNT SERIES WS-50E30SS WS-50E36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed for indoor residential use only. DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT. Please read this operation manual thoroughly before using your range hood. Store it in a safe location for when you need to reference it in the future.
TABLE OF CONTENTS 1 Table of Contents Safety Information .............................................................. 2 – 3 Content Checklist ..................................................................... 4 Measurements ........................................................................... 5 Preparation ................................................................................ 6 Installation ...........................................................................
2 SAFETY INFORMATION SAFETY INFORMATION TO REDUCE THE RISK OF A FIRE, ELECTRICAL SHOCK, AND/OR INJURY OBSERVE THE FOLLOWING: • • • • • • • • • Unit is intended for indoor residential use only. If you should have questions, contact the manufacturer at the address or telephone number listed in the warranty. In case the unit should need to be cleaned or repaired, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
SAFETY INFORMATION 3 TO REDUCE THE RISK OF FIRE, OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. • • • • • Regardless of heat level, never leave any surface materials unattended while operating an open flame. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). Depending on amount of usage, clean ventilating fans and filters frequently.
4 CONTENT CHECKLIST CONTENT CHECKLIST 1. CONTENTS INCLUDED a. (1) WS-50E series(30”, 36”)hood assembly b. (1) Lower duct cover (14-1/4”) c. (1) Upper duct cover (13-3/4”) d. (1) User’s manual e. (1) 6”/ 7” transition collar f. (2) Aluminum filters/ Baffle filters (30” model only) g. (3) Aluminum filters / Baffle filters (36” model only) h. (1) Screw packet 2. CONTENTS NOT INCLUDED a. WS-50EEXTDC (Extension duct cover) b. WS-50EDK (Ductless kit) c. WS-50ECFMR (CFM reducer) d.
MEASUREMENTS 5
6 PREPARATION PREPARATION 1. BEFORE YOU START **BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT** **DO NOT INSTALL IF DAMAGED** **RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED** a. Be sure you have all the content of your purchase and required tools for this installation. b. Installation may take at least 1 to 2 hours from start to finish. c. Plan to use as few elbows or turns as possible for more efficient air flow. d. Collar size may need to be increased if utilizing a long duct run. e.
INSTALLATION 7 INSTALLATION 1. WALL MOUNT INSTALLATION a. Make sure all preparation steps are completed. b. Determine your ceiling height to see if you need an extension. i. Hood unit height = 10-1/2” ii. Duct cover height = 14-1/4” (lower) 13-3/4” (upper) iii. Minimumheight (duct cover only) = 14-1/4” iv. Ductless Mode Minimum height = 18-1/4 v. Maximum height (duct cover only) = 27-1/4” vi. (OPTIONAL) Extension duct cover height = 46-3/4” c.
8 INSTALLATION 3. COLD WEATHER INSTALLATION (OPTIONAL) a. Check with your local building codes to see if a CFM reducer is an acceptable alternative to make-up air. b. Open the WS-50ECFMR (CFM reducer) and inspect for any sign of defect or damage. (ie. Cracks, broken flips) c. AFTER COMPLETING Step A – G of Section 1 WALL MOUNT INSTALLATION d. Place the CFM reducer onto the outlet of the unit and seal the connection point with aluminum tape. (Be sure it is secure with no opening or gaps) e.
INSTALLATION DIAGRAM INSTALLATION DIAGRAM 9
10 OPERATION & FEATURES OPERATION & FEATURES 1. EASY ACCESS CONTROL SWITCH (from left to right) a. Button 1 –Lights ON/OFF b. Button 2 – Decrease speed c. Button 3 –Increase speed d. Button 4 –Power ON / OFF 2. HALOGEN / LED LIGHTS a. A set of (2) Halogen lamp will be included. b. Additional Halogen or LED lamp may be purchased separately. c. Light socket can accommodate both halogen and LED lamps without the need to change the transformer. 3.
OPERATION & FEATURES 4.
12 OPERATION & FEATURES 5. CHARCOAL FILTERS **DO NOT WASH CHARCOAL FILTERS! IT WILL DISSOLVE!!** a. Insert the charcoal filters on each side of the motor on top of the white protective grill as shown below. (Fig. 3a) Fig. 3a b. Rotate the charcoal filters in a counter-clockwise motion until you hear a click. (Fig. 3b) Fig. 3b c. Installation is complete after the charcoal filters are secured in place.
CLEANING & MAINTENANCE 13 CLEANING& MAINTENANCE WARNING!!! To prevent the possibility of a fire and explosion, do not use flammable liquids or solvents to clean the unit or any of its parts. Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning. Please thoroughly clean the unit weekly as stainless steel can rust under certain condition or by improper cleaning. 1. RANGE HOOD a.
TROUBLESHOOTING 14 TROUBLESHOOTING WARNING!!! Check to make sure all power sources are disconnected before starting any troubleshooting. Safety gloves and glasses should be worn when working on the unit. Serious injury or death may occur if safety precautions are not followed. WS-50E Series Light issue (All not turning on) 1. LED lights may need to be changed. 2. New Transformerreplacement is required. Halogen/LED light issue 1. Check all wiring to and from the unit. 2.
PART LIST / REPLACEMENT PART LIST / REPLACEMENT # Description # Description 1 2 Duct cover bracket 9 Capacitor Duct cover 10 Control switch 3 6” collar 11 Motor 4 Duct cover panel 12 Aluminum Filters 5 Hood bracket 6 Hood body assembly 7 Halogen / LED lights 8 Light cover 15
16 WARRANTY / CONTACT US WARRANTY / CONTACT US LIMITED WARRANTY Windster Hoods Inc. warrants its product against defects in material or workmanship as follows: Labor:For a period of one (1) year from the date of purchase, if the product is determined to be defective, Windster will attempt to repair the product, at its option, at no charge. After the warranty period, customer must pay for all labor charges.
WARRANTY / CONTACT US 17 WHAT IS NOT COVERED BY MANUFACTURE WARRANTY 1. Damages resulting from any of the following: a. Improper installation or maintenance b. Any repair, modification, alteration or adjustment not authorized by the manufacturer or an authorized service dealer c. Misuse and/or accidents d. Incorrect electric current, voltage or power supply e. Improper setting of any control (Pressing multiple selections at the same time) f. 2.