LIMITED WARRANTY This warranty extends to the original purchaser only. This warranty is not transferable, between homes or owners an only applicable to residential use. Windily Industries, LLC provides a 3-year limited parts warranty for all range hoods. Under this warranty, you {the customer), is entitled to replacement parts at no cost to repair and restore functionality if any part of the product were to fail. No labor is provided.
( IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, READ THE FOLLOWING: » Use this unit only in the manner intended by the manufacturer. If you have questions, please contact the manufacturer. >» Before servicing or cleaning the unit, switch the power off and turn power off at the electrical panel and lock the service panel. This will prevent the power from accidentally turning on.
( LOCATION REQUIREMENTS ] IMPORTANT: Observe all governing codes and ordinances. Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. Canopy hood's location should be away from strong draft areas, such as windows, doors, and strong heating vents. Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for all vent pieces used in the system. ( INSTALLATION DIMENSION RECOMMENDATIONS ] For wall mount range hoods: YVES Counter top Height. Hood height from ceiling to bottom of the range hood filter surface: 24” minimum from cooking surface up to 36” maximum for Electric/Induction range tops. 26” minimum from cooking surface up to 36” maximum for Gas range tops. Floor to ceiling height.
Parts not supplied >» Duct tape » Preinstalled ventilation system and duct work » Preinstalled outside duct cap or weatherproofing Installing the range hood This installation is for mounting the product to a ceiling. Ensure your ceiling has the proper support to hold the range hood weight. These instructions are general guidelines, please consult professional installation specialist regarding the best type of mounting hardware and support system based on your ceiling construction.
9. Attach the (4) upper support frame brackets (E} to the ceiling mounting bracket (1). Each support bracket will use Screws (H). 10. Measure the distance that the bottom of the range hood will be from the top of your range (see page 5 for reference). Attach the (4) lower support frame brackets {E) to the upper support frame brackets {E). Each support bracket will use Screws (H).
Detach the outer duct cover {I} by removing the {2} set screws near the bottom middle of the attached duct. Inside the duct, there are tongue and groove clips for stability. Lift on side of the duct to detach. Ll] Bring the two duct pieces together over the support frame brackets and the upper duct that was attached in step 15. Reattach the (2) set screws. Make sure the tongue and groove clips are realigned. Side View Outer Chimney Back Outer Chimney Front.
OPERATING INSTRUCTIONS Note: There are different operating instructions based on the control panel for your model. Please choose the operating instruction for your unit. Powering on/off and Set tin, Lamp Timer Minus Clock Plus Fan Power/Standby » Lamp: Press the lamp display one time to activate the light, press the lamp display again to deactivate it. >» Power/Standby: When the range hood is in the “original” state, touch this button. It will enter the standby mode.
start at F6 speed for 5 seconds for an initial suction burst then it will automatically reduce to F5 speed. If the button is pressed again, the speed will stay the same. » To lower or Increase the fan speed press the Plus or Minus buttons. » When fan is in the standby mode, press the Fan button to reach maximum speed immediately. Touching this button while in a lower speed will automatically take to the maximum speed. Touching the Fan button twice will turn the fan off.
CARE and MAINTENANCE Cleaning IMPORTANT: Clean the hood and panel filters frequently per the following instructions. Replace the panel filters before operating hood. Exterior Surfaces To avoid damage to the exterior surface, do not use steel wool or soap filled scouring pads. Always wipe dry to avoid water marks. Cleaning Method Use liquid mild-detergent soap and water, do not use hard abrasive cleaners. Wipe with damp soft cloth or non-abrasive sponge, then rinse with clean water and wipe dry.