Installation&Assembly

5
Rear Discharge
A 90-degree elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, certain hoods can be used in the non-vented
(recirculating) version, fitting a carbon filter at the motor. Fumes and vapors are the recycled through the top
grille. DO NOT block the chimney holes.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for all vent pieces used in the
system.
INSTALLATION DIMENSION RECOMMENDATIONS
For wall mount range hoods:
A. Countertop Height.
B. Hood height from ceiling to bottom of the range hood filter surface: D-A-C=B.
C. 24” minimum from cooking surface up to 36” maximum for Electric/Induction range tops. 27” minimum
from cooking surface up to 36” maximum for Gas range tops.
D. Floor to ceiling height.
Prior to installation
Unpack range hood and ensure all listed parts are in the box.
It is recommended for the vent system to be installed before hood is installed.
Before making cutouts, make sure there is proper clearance within the ceiling or walls for the exhaust
vent.
Determine which venting method to use: roof or wall.
It is recommended that a professional installer perform the range hood installation.