SPECIFICATIONS
Power Requirement 12/24 VDC 100 mA
12/24 VAC 200 mA
Probe Sensitivity Will not alarm due to high humidity or condensation.
Operating Temp 32˚ to 130˚F (0˚ to 54˚C); non-condensing environment
Indoor use only.
Output 1 Form C Relay (SPDT)
1 Amp @ 24 VDC, resistive
Buzzer 85dBA @ 10 cm @ 12 VDC, 2.4kHz pulsed (with silence feature)
Probe Options Includes 4 Standard Supervised Surface Probe (W-S-S)
Accepts up to 8 Supervised (W-S-S or W-UC-S) or up to
16 Unsupervised Probes (W-S-U or W-UC-U)
Probes may be either Surface or Under Carpet
Max Cable Length 500’ (152.4 m) max
Probe Cable Probes include 15” (4.6 m) cable.
Extend using 22-18 AWG twisted pair.
Console Weight 1 lb (0.45 kg)
Console Dimensions 6.55 x 4.70 x 1” (16.6 x 11.9 x 2.5 cm)
Probe Dimensions Surface: 2 x 3 x 0.88” (5.1 x 7.6 x 2.2 cm)
Under Carpet: 2 x 3 x 0.18” (5.1 x 7.6 x 0.5 cm)
Mounting Included standard 3-gang box
Case Material ABS
Warranty 1 Year Limited
CONTENTS
This package contains:
1 WB-800
4 Surface Probes - Supervised (W-S-S)
1 Standard 3-Gang Metal Mounting Box
4 Phillips screws for mounting
1 Installation/Operating Instruction Guide
WB-800
ADDITIONAL PROBES AND ACCESSORIES
W-S-S WB Surface Probe Supervised
(Up to 8 per WB-800 console)
W-UC-S WB Undercarpet Probe Supervised
(Up to 8 per WB-800 console)
W-S-U WB Probe Unsupervised
(Up to 16 per console)
W-UC-U WB Probe Undercarpet Unsupervised
(Up to 16 per console)
12VDCT 12VDC Transformer Wall Mount Power Supply
BZ-1 Remote Annunciator
Note: Supervised probes are recommended for new WB-800 installations.
MONITORING THE ABSENCE OF WATER:
The WB-800 is not recommended to be used to detect absence of water. The WB-200
is recommended for this type of application.
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. (“Winland”) warrants to the end user/purchaser that each product of its manufacture shall
be free from defects in material and factory workmanship for a period of one year from the date of purchase, when
properly installed and operated under normal conditions according to Winland’s instruction.
Winland’s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts
thereof which shall be returned to the factory, by the original purchaser, transportation charges prepaid, within
one year of the date of purchase and which upon examination, shall disclose to Winland’s satisfaction to have been
originally defective. Correction of such defects by repair to, or supplying replacements for, defective parts shall
constitute fulfillment of all Winland’s obligations to purchaser under this limited warranty. Repair service performed
by Winland after one year from date of purchase will be for a reasonable service charge.
This limited warranty shall not apply to any of Winland’s products which have been subject to misuse, negligence
or accident or which have been repaired or altered outside of Winland’s factory. The warranty is void if the Product’s
housing or cover is removed.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use of its products
or any other cause.
This warranty shall be null and void in its entirety if: (i) the product is altered or modified in any way that is not
consistent with the manufacturer’s instructions, or (ii) the product is used with or connected to a device: (a) that
such product is not intended to be used with or connected to, (b) is not otherwise consistent with the manufacturer’s
instructions, or (c) is not otherwise approved by the manufacturer.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY
WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT AND TITLE, AND ANY
WARRANTIES ARISING FROM COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS
MADE TO THE END USER/PURCHASER BY ANY OTHER PARTY ARE ALSO EXCLUDED.
WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY OR OTHER CONTRACT, NEGLIGENCE OR OTHER TORT, OR
OTHERWISE. Under no circumstances shall Winland’s liability under this limited warranty exceed the purchase price
paid by the end user/purchaser for the product.
No person, agent or dealer is authorized to give warranties on behalf of Winland nor to assume for Winland any other
liability in connection with any of its products.
PRODUCT AND ACCESSORY GUIDE
EA200-12
EA200-24
EA400-12
EA400-24
EA800
EA800-ip WB-200 WB-350 WB-800
W-S-S W-S-S W-S-S W-S-S
W-UC-S W-UC-S W-UC-S W-UC-S
W-S-U W-S-U W-S-U
W-UC-U W-UC-U W-UC-U
W-S-S (Water Probe, Surface, Supervised) and W-UC-S (Water Probe, Under Carpet, Supervised)
The supervised surface probe can be connected to the EnviroAlert products as well as the WB-800. The alarm will be activated if water is present as well as if the cable is cut.
W-S-U (Water Probe, Surface, Unsupervised) and W-UC-U (Water Probe, Under Carpet, Unsupervised)
The standard surface probe is unsupervised and can be connected to the full line of WaterBug products. No alarm will sound if the cable is cut.
WaterBug® WB-200 (12 or 24 VAC/DC)
6 Zone Unsupervised Water Probe:
Includes 1 unsupervised surface probe (W-S-U)
Accommodates up to 6 probes in parallel
May purchase under carpet probe (W-UC-U)
Will not alarm due to condensation or humidity
Can be used to detect absence of water
WaterBug® WB-350 (9V battery)
6 Zone Unsupervised Water Probe:
Includes 1 unsupervised surface probe (W-S-U)
Accommodates up to 6 probes in parallel
May purchase under carpet probe (W-UC-U)
Will not alarm due to condensation or humidity
Built-in audible alarm with low battery notification
EnviroAlert® EA200
Dual Zone Wireless Electronic Monitor:
Temperature, Humidity, Water Presence
EA200-12 (12VDC) and EA200-24 (24VDC)
Has one built-in ambient temperature probe
Connect up to 1 hard wired probe
EnviroAlert® EA400
Four Zone Wireless Electronic Monitor:
Temperature, Humidity, Water Presence
EA400-12 (12VDC) and EA400-24 (24VDC)
Connect up to 4 hard wired probes
EnviroAlert® EA800
Eight Zone Wireless Electronic Monitor:
Temperature, Humidity, Water, Closed Contact, 4-20mA
Connect up to 4 wireless and up to 4 wired probes
Automatic data logging transferable via USB stick
Probe data
Event and alarm history
EnviroAlert® EA800-ip
Eight Zone Wireless Electronic Monitor:
Temperature, Humidity, Water, Closed Contact, 4-20mA
Connect up to 4 wireless and up to 4 wired probes
Remote access via wired IP connection to
Programming and real-time data viewing
Probe data as well as alarm and event logs
Tech Support 8:00am - 5:00pm Central Time
(800) 635-4269 • +1-507-625-7231 P
www.winland.com