User manual
2U Rack Series User Manual
68
Thermal Configuration
SETTING
DESCRIPTION
Automatic thermal
reporting
Configure _CRT,_PSV and _ACO automatically based on
values recommended in BWG’s thermal reporting for
thermal management settings. Set to disabled for
manual configuration.
Active trip point 0 fan
speed
Active trip point 0 fan speed in percentage.
Active trip point 1
This value controls the temperature of the ACPI active
trip point 1- the point in which the OS will turn the
processor fan on active trip point1 fan speed.
Active trip point 1 fan
speed
Active trip point 1 fan speed in percentage.
Passive TC1 value
This value sets the TC1 value for the ACPI passive cooling
formula.
Passive TC2 value
This value sets the TC2 value for the ACPI passive cooling
formula.
Passive TSP value
This value sets the TSP value for the ACPI passive cooling
formula.