Picture 11 Temperature information
Click get to see the working temperature information. For normally, the temperature
range is between -40 85 degree Celsius.
When the “temperature protect” is activated (the default is turn on), once the temperat
ure is over 65, the rate of inventory would fell by 50%; If the temperature is over
85, the reader-module would stop working automatically, and it would back to work
again only the temperature below 85.
More than 80 on the life of the module will have a certain impact.
2.10 Recommended link setting
Link setting is in basic settings as below picture.
Picture 12 Recommended link setting
Recommended Link Settings:
DSB_ASK /FM0/40KHz
PR_ASK/Miller 4/250KHz
PR_ASK/Miller 4/300KHz
DSB_ASK /FM0/400KHz
Default Link setting is PR_ASK/Miller 4/250KHz.
Choose save, the setting will be kept after power off.
2.11 Antenna setting
Antenna setting is in Basic Setting as below picture.
Picture 13 Antenna setting
ANT2, ANT3, ANT4 are not applied for single port module. For four channels module
and reader, you could choose one or more antennas to work, and also can set the
working time for each antenna.
2.12 Multiple inventory Delay time setting
Multiple inventory delay time setting is in Basic Setting, as below picture.