User Manual

JDY-25M Super BLE Bluetooth Module
17
As there are too many functions of MESH network, it will not be described in detail in this document. Please refer
to the document of Instructions for use of mesh. PDF.
25Set/query - Key input pin function
Instruction Response Parameter
AT+KEY<Param1>
<Param2>
<Param3>
<Param4>
OK
Param1
Indicates input IO number
(1-5)
Param2
Target address(0000 to ffff)
Param3
Target output IO number
(1-5)
Param4
Whether the target device
prints output (0-1) from the serial port
at the same time after receiving the
instruction, 0 means no serial port
output, 1 means simultaneous serial
port output
AT+KEY<Param1>
+KEY=<Param1>
<Param2>
<Param3>
<Param4>
26Set/query - MESH network ID number
Instruction Response Parameter
AT+NETID<Param1> OK Param1:(0000 to FFFF
AT+NETID +NETID=<Param1>
Instruction: The ID number of the network within the same network must be the same, otherwise the network
cannot be established.
27Set/query - MESH short address
Instruction Response Parameter
AT+MADDR<Param1> OK Param1:(0001 to FFFF
AT+MADDR +MADDR=<Param1>
Instruction: The function of the short address in the network is the unique ID number of each device. The same
short address cannot appear in the same network. The short address is configured by AT instruction, and it can also
be automatically assigned. To automatically assign the address, you need to turn on the central machine, and
automatically assign the ID to the device that enters the network for the first time through the central machine. It is
generally recommended that the user configure the short address by AT instruction himself.
28Set/query - Mesh network device type
Instruction Response Parameter
AT+MCLSS<Param1> OK Param1:(0-1
0Router (supports relaying)
1Terminal device (without
relay function)
AT+MCLSS +MCLSS=<Param1>
Instruction: Router supports data relay, not low power consumption