User's Manual

5 of 6
“A” Display automatic mode (manual=0, master=1, slave=2, service=3, service-master=4)
“A0” Manual mode
“A1” Cable-slave mode. The AIRcable becomes discoverable and will be in pairing mode if no
pairing information has been stored. Then it will be not discoverable and will allow
connections only from the paired partner. In this mode, only the SPP profile is active.
“A2” Cable-master mode: do inquiry first, then pairing with the configured PIN number, then
connect as master (not discoverable).
“A3” Service-slave Mode: Use the authentication, profiles, pin number and name configured
before. (*)
“A4” Service-master mode. If authentication is enables it first discovers a partner, tries to pair
with it and makes a connection. If authentication is disabled, it discovers a partner and
tries to connect to it. It uses the PIN number configured before.
"U" UART configuration command. Display the settings in hex: "UART: 0x6". It is an add up of
the following: external switches enabled: 6, even parity: 4, odd parity: 2, two stop bits: 1.
“UN1E” Configure the UART: First letter is parity: none=N, E=even, O=odd. Second is number of
stop bits: 1=one, 2=two. Third letter enables the external baud rate switches: external=E,
internal=I.
“UE2I” Example 2: Even parity, 2 stop bits, internal baud rate settings.
"UO1E" Example 3: Odd parity, 1 stop bit, external switches enabled.
"T" Display the baud rate of the UART after a connection has been established. "BAUD: 0"
means that the external switches determine the baud rate.
"T472" Set the baud rate while connected to this value. It is a 3 digit decimal value with leading
zeros to this formula: baud * 0.004096. Example: set baud to 115200. (*)
"K" AIRcable USB only: command to configure hardware handshake
"K1" Disable hardware handshake, this is for poorly written MS applications.
Use the dip switches on the AIRcable Serial modules.
“Z” Remove pairing information and go into manual mode (*)
“X0” Disable debug mode
“X1” Switch debug mode on, print status information
“Y” Send a “cancel” command to abort any ongoing activity.
"K" AIRcable USB has the ability to switch off hardware handshake. Use "K1" to disable
hardware handshake and "K0" to enable hardware handshake.
"F" Display the sniff max interval: "SNIFF 0x0"
“F000” Specify the maximum sniff interval for slave connections. “000” means, sniff is off, “540” is
the maximum. The three digits are in hex specifying the number of slots.
"V" Display the page scan interval window: PAGESCAN INTV/WIND: 0x800/0x12"
"V08000012" Set the page scan interval to 0x0800 and the window to 0x0012
Note that the (*) in the description means that this command may reset the processor. Wait for 3 seconds before issuing another command.
Operational Specification
Range: 10m in open office conditions
Electrical Requirements:
VCC power supply 5V 12V
VIH high level input 2.0V 12V
VIL low level input -12V 0.8V
VOH high output level 3V
VOL low output level -3V
Power consumption
Connected 42 73 mA
Connected standby 3 52 mA
Waiting to connect 42 55 mA
Waiting to connect standby 2 21 mA