User manual
Company Condential Proprietary
XMC-M25 Interface cable
V0
X10DR
¥
150cm
"J1"
FEMALE, 15-CONTACT
D-SUB CONNECTOR
WG*15C +ADB
unstripped
unstripped
50cm
1
3
4
5
6
7
8
9
13
Drain connects to shell
Switched B+ from radio
Ext Mic Hi
Mic Lo to radio
Received audio from radio
Ext PTT to radio
Emergency out to radio
COR/ Audio unmute from radio/TOR
DC/ Digital Ground
Remote/ footswitch/Handle bar PTT
DB15 F
1A FB fuse
15
10
6
1
13
**
DB25 -M Connector
Notes:
Need to remove shorting jumper on radio TIB 
to enable Emergency function. 
SJ1&2 may need to be swapped on X-ponder 
PCB if radio needs NC Emergency input. See 
X10DR user manual.
**PM1500 does not provide a COR output. 
so default operation of X10DR will be using 
Rx voice detect. (may cause some small voice 
clipping) 
Alternatively, you may be able to re-congure 
internal jumpers on TIB to allow a switched 
ground indicate of “radio speaker unmute” to 
be applied to DB25 Pin 5 for COR.
BLK/WH
BLK/WH
* or Purple
** or Purple /White
S
BLK
BRN
RED
ORG
YEL
GRN
BLU
PUR
GRY
BLK/WH
DB25 -M connector